Transcranial optical path length in infants by near-infrared phase-shift spectroscopy
- 1 March 1995
- journal article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 11 (2) , 109-117
- https://doi.org/10.1007/bf01617732
Abstract
Background. Near-infrared spectroscopy (NIRS) is an emerging technique for noninvasive, bedside monitoring of cerebral oxygenation and blood flow. Traditionally, it has relied on the Beer's Law relationship in which the concentration of light-absorbing oxygen-carrying pigments is proportional to their light absorbance, and inversely proportional to an optical path length (a measure of the distance traveled by photons passing through the tissue). In practice, NIRS has been based upon assumptions that mean transcranial optical path length, the average optical path length for a given patient, is constant among patients and independent of the wavelength of light used.Objective. The objective of our study was to measure mean optical transcranial path length in infants as a step in allowing quantitation of cerebral oxygenation.Methods. We measured mean transcranial optical path length in 34 infants, aged 1 day to 3 years, using amplitude-modulated phase-shift spectroscopy at 754 nm and 816 nm. Optical transcranial path lengths (mean±SEM) were 8.6±0.9 cm, 11.1±0.9 cm, and 11.3±0.9 cm at 754 nm, and 8.8±0.9 cm, 11.2±0.8 cm, and 11.1±0.9 cm at 816 nm, using emitter-detector separations of 1.8, 2.5, and 3.0 cm, respectively. Optical path length increased as emitter-detector separation, head circumference, or age increased. Variance in the ratio of mean optical path lengths at the two different wavelengths exceeded that accounted for by variation in repeated measures alone (pConclusions. NIRS instrument emitter-detector geometry, subject age, head size, and wavelength used each influence optical path length. Quantitative NIRS measurements in clinical use may require concurrent measurement of both absorbance and optical path length at each wavelength, or use of newer measures that are not based upon Beer's Law assumptions.Keywords
This publication has 46 references indexed in Scilit:
- Optical Time-of-Flight and Absorbance Imaging of Biologic MediaScience, 1993
- Properties of photon density waves in multiple-scattering mediaApplied Optics, 1993
- Coherent backscattering in biological media: measurement and estimation of optical propertiesApplied Optics, 1993
- Line scan acquisition for time-resolved imaging through scattering mediaOptical Engineering, 1993
- Tissue characterization and imaging using photon density wavesOptical Engineering, 1993
- The theoretical basis for the determination of optical pathlengths in tissue: temporal and frequency analysisPhysics in Medicine & Biology, 1992
- Experimental tests of a simple diffusion model for the estimation of scattering and absorption coefficients of turbid media from time-resolved diffuse reflectance measurementsApplied Optics, 1992
- Ballistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr GateScience, 1991
- Time resolved reflectance and transmittance for the noninvasive measurement of tissue optical propertiesApplied Optics, 1989
- Effects of crying on cerebral blood volume and cytochrome aa3The Journal of Pediatrics, 1988