Simultaneous Measurement of Ion Ratios by Inductively Coupled Plasma-Mass Spectrometry with a Twin-Quadrupole Instrument
- 1 November 1994
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 48 (11) , 1360-1366
- https://doi.org/10.1366/0003702944027958
Abstract
The ion beam from the inductively coupled plasma (ICP) is split into two parts by a device comprised of two electrostatic analyzers in a back-to-back arrangement. Each ion beam is then monitored by a separate quadrupole mass analyzer and electron multiplier. Thus, ion ratios can be measured simultaneously without scanning. Isotope ratios for copper are measured with a precision of 0.14% relative standard deviation (RSD). Internal standard ratios for Co+/La+ are measured with a precision of 1% RSD. Ion signals in the two channels are highly correlated, and the magnitude of flicker noise is reduced in the resulting ratios. Bias in the measured isotope ratios is substantial but can be corrected by calibration.Keywords
This publication has 30 references indexed in Scilit:
- Occurrence and reduction of noise in inductively coupled plasma mass spectrometry for enhanced precision in isotope ratio measurementJournal of Analytical Atomic Spectrometry, 1994
- Precise determination of iron isotope ratios in whole blood using inductively coupled plasma mass spectrometry. Invited lectureJournal of Analytical Atomic Spectrometry, 1992
- Verification of a correction procedure for measurement of lead isotope ratios by inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1991
- Optimization of the mass scanning rate for the determination of lead isotope ratios using an inductively coupled plasma mass spectrometerJournal of Analytical Atomic Spectrometry, 1991
- Application of ICP-MS to accurate isotopic analysis for human metabolic studiesSpectrochimica Acta Part B: Atomic Spectroscopy, 1987
- Matrix-effect observations in inductively coupled plasma mass spectrometryJournal of Analytical Atomic Spectrometry, 1987
- Isotope ratio determinations by inductively coupled plasma/mass spectrometry for zinc bioavailability studiesAnalytica Chimica Acta, 1986
- Improved performance using internal standardization in inductively-coupled plasma emission spectroscopySpectrochimica Acta Part B: Atomic Spectroscopy, 1983
- Spatial characterization of analyte emission and excitation temperature in an inductively coupled plasmaSpectrochimica Acta Part B: Atomic Spectroscopy, 1982
- The vertical spatial characteristics of analyte emission in the inductively coupled plasmaSpectrochimica Acta Part B: Atomic Spectroscopy, 1981