Stereotactic 11-Gauge Vacuum-Assisted Breast Biopsy: A Validation Study

Abstract
OBJECTIVE. The aim of our study was to determine the false-negative rate of stereotactic 11-gauge vacuum-assisted biopsy in a validation study of lesions that had subsequent surgical excision.MATERIALS AND METHODS. Retrospective review was performed of 318 lesions that underwent stereotactic 11-gauge vacuum-assisted biopsy and subsequent surgical excision. A false-negative case was defined as a pathologically proven cancer in which stereotactic biopsy yielded benign results without atypia. Medical records, imaging studies, and histologic findings were reviewed.RESULTS. False-negative findings were encountered at stereotactic 11-gauge vacuum-assisted biopsy in 3.3% (7/214) of pathologically proven cancers. False-negative findings occurred in 3.5% (4/115) of malignant calcification lesions versus 3.0% (3/99) of malignant masses (p = 1.0). The seven false-negative findings included five Breast Imaging Reporting and Data System (BI-RADS) category 5 lesions that yielded benign results at biopsy, one BI-RADS ca...