L-Cysteine as a reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry—Part 1. Optimization of the analytical parameters
- 1 January 1993
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 118 (11) , 1417-1423
- https://doi.org/10.1039/an9931801417
Abstract
L-Cysteine was investigated as the reducing and releasing agent for the determination of antimony and arsenic using flow injection hydride generation atomic absorption spectrometry with the aim of replacing the previously used potassium iodide. The prereduction of the pentavalent to the trivalent form at room temperature was completed within 5 and 30 min for antimony and arsenic, respectively, which was essentially identical with the performance of potassium iodide. However, much lower acid and reagent concentrations were required with L-cysteine than with potassium iodide. In addition, even dilute analyte solutions containing L-cysteine were stable for at least one week, whereas solutions containing potassium iodide had to be prepared fresh daily. Under optimized conditions, in the presence of 1% m/v L-cysteine and 1 mol l–1 HCI for antimony or 0.1 mol l–1 HCI for arsenic, detection limits (three times the standard deviation of a blank solution, n= 10) of 0.05 and 0.01 µg l–1 were obtained for antimony and arsenic. The calibration graphs were linear (r > 0.999) for up to 10 µg l–1 of antimony and 5 µg l–1 of arsenic, using integrated absorbance for evaluation. The precision was better than 2% relative standard deviation (n= 10) for both elements at the 5 µg l–1 concentration level.Keywords
This publication has 31 references indexed in Scilit:
- Interferences from hydride-forming elements on selenium in hydride-generation atomic absorption spectrometry with a heated quartz tube atomizerSpectrochimica Acta Part B: Atomic Spectroscopy, 1993
- Nonequilibrated sample manipulation—The essence of flow-injection analysisMicrochemical Journal, 1992
- A study of arsenic(III) and arsenic(V) reduction and of arsine decomposition in hydride-generation atomic absorption spectrometryAnalytica Chimica Acta, 1987
- Hydride-generation atomic absorption spectrometry coupled with flow injection analysisAnalytical Chemistry, 1985
- Flow injection analysis for the determination of bismuth by atomic absorption spectrometry with hydride generationAnalytical Chemistry, 1982
- Determination of antimony, arsenic, bismuth, selenium, tellurium, and tin in metallurgical samples using the hydride AA technique—I: Analysis of low-alloy steelsSpectrochimica Acta Part B: Atomic Spectroscopy, 1981
- Determination of “inorganic” arsenic(III) and arsenic(V), “methylarsenic” and “dimethylarsenic” species by selective hydride evolution atomic-absorption spectroscopyThe Analyst, 1981
- Evaluation of a method for determination of total antimony, arsenic and tin in foodstuffs using measurement by atomic-absorption spectrophotometry with atomisation in a silica tube using the hydride generation techniqueThe Analyst, 1979
- Determination of volatile hydride-forming metals in steel by atomic absorption spectrometryAnalytica Chimica Acta, 1976
- The determination of arsenic(III) and total arsenic by atomic-absorption spectroscopyThe Analyst, 1976