Uniform magnetic fields and double‐wrapped coil systems: Improved techniques for the design of bioelectromagnetic experiments
- 1 January 1992
- journal article
- research article
- Published by Wiley in Bioelectromagnetics
- Vol. 13 (5) , 401-411
- https://doi.org/10.1002/bem.2250130507
Abstract
A common mistake in biomagnetic experimentation is the assumption that Helmholtz coils provide uniform magnetic fields; this is true only for a limited volume at their center. Substantial improvements on this design have been made during the past 140 years with systems of three, four, and five coils. Numerical comparisons of the field uniformity generated by these designs are made here, along with a table of construction details and recommendations for their use in experiments in which large volumes of uniform intensity magnetic exposures are needed. Double‐wrapping, or systems of bifilar windings, can also help control for the non‐magnetic effects of the electric coils used in many experiments. In this design, each coil is wrapped in parallel with two separate, adjacent strands of copper wire, rather than the single strand used normally. If currents are flowing in antiparallel directions, the magnetic fields generated by each strand will cancel and yield virtually no external magnetic field, whereas parallel currents will yield an external field. Both cases will produce similar non‐magnetic effects of ohmic heating, and simple measures can reduce the small vibration and electric field differences. Control experiments can then be designed such that the only major difference between treated and untreated groups is the presence or absence of the magnetic field. Double‐wrapped coils also facilitate the use of truly double‐blind protocol, as the same apparatus can be used either for experimental or control groups. 1992 Wiley‐Liss, Inc.Keywords
This publication has 15 references indexed in Scilit:
- Is Geomagnetic Sensitivity Real? Replication of the Walker-Bitterman Magnetic Conditioning Experiment in Honey BeesAmerican Zoologist, 1991
- Constraints on biological effects of weak extremely-low-frequency electromagnetic fieldsPhysical Review A, 1991
- Magnetite biomineralization and geomagnetic sensitivity in higher animals: An update and recommendations for future studyBioelectromagnetics, 1989
- Chronic exposure of primates to 60‐Hz electric and magnetic fields: I. exposure system and measurements of general health and performanceBioelectromagnetics, 1989
- Conditioning analysis of magnetoreception in honeybeesBioelectromagnetics, 1988
- Magnetic compass orientation in the Eastern red-spotted newt (Notophthalmus viridescens)Journal of Comparative Physiology A, 1986
- Biogenic magnetite as a basis for magnetic field detection in animalsBiosystems, 1981
- An attempt to confirm magnetic sensitivity in the pigeon,Columba liviaJournal of Comparative Physiology A, 1976
- Square cross section coils for the production of uniform magnetic fieldsJournal of Scientific Instruments, 1967
- Design of Square Helmholtz Coil SystemsReview of Scientific Instruments, 1966