Transient response of aerobic and anoxic activated sludge activities to sudden substrate concentration changes
- 11 March 2004
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 86 (3) , 277-290
- https://doi.org/10.1002/bit.20032
Abstract
The state‐of‐the‐art understanding of activated sludge processes as summarized in activated sludge models (ASMs) predicts an instantaneous increase in the biomass activity (which is measured, e.g., by the corresponding respiration rate OUR, NUR, etc.) under sudden substrate concentration changes. Experimental data (e.g., short‐term batch respiration experiments under aerobic or anoxic conditions) collected for the calibration of the dynamic models (ASMs) often exhibit a transient phenomenon while attaining maximum activity, which cannot be explained by the current understanding of the activated sludge process. That transient phenomenon exhibits itself immediately upon addition of a substrate source to an endogenously respiring activated sludge sample and it usually takes a few minutes until the activated sludge reaches its maximum possible rate under given environmental conditions. This discrepancy between the state‐of‐the‐art model and the experimental data is addressed in detail in this investigation. It is shown that the discrepancy is not caused by an error in the experimental set‐up/data but it is rather due to model inadequacy. Among the hypotheses proposed, it appears that this transient response of the activated sludge most likely results from the sequence of intracellular reactions involved in substrate degradation by the activated sludge. Results from studies performed elsewhere with pure cultures (S. cerevisae and E. coli) support the hypothesis. The transient phenomenon can be described by a dynamic metabolic network model or by a simple first‐order model, as adopted in this study. The transient phenomenon occurring in short‐term batch respiration experiments is shown to interfere severely with parameter estimation if not modeled properly (2.8%, 11.5%, and 16.8% relative errors [average of three experiments] on YH, μmaxH, and KS, respectively). Proper modeling of this transient phenomenon whose time constant is on the order of minutes (1 to 3 min) is expected to contribute fundamentally to a better understanding and modeling of Orbal, carousel, and SBR‐type treatment plants with fast‐alternating process conditions, although such studies are beyond the scope of this report.Keywords
This publication has 38 references indexed in Scilit:
- Modeling aerobic carbon source degradation processes using titrimetric data and combined respirometric-titrimetric data: Experimental data and model structureBiotechnology & Bioengineering, 2002
- Modeling aerobic carbon source degradation processes using titrimetric data and combined respirometric–titrimetric data: Structural and practical identifiabilityBiotechnology & Bioengineering, 2002
- Dynamic modeling of the central carbon metabolism of Escherichia coliBiotechnology & Bioengineering, 2002
- Activated sludge monitoring with combined respirometric–titrimetric measurementsWater Research, 2001
- Characterization of Simultaneous Nutrient Removal in Staged, Closed‐Loop BioreactorsWater Environment Research, 2000
- Variability in kinetic parameter estimates: A review of possible causes and a proposed terminologyWater Research, 1996
- NDBEPR PROCESS OPTIMIZATION IN SBRs: REDUCTION OF EXTERNAL CARBON-SOURCE AND OXYGEN SUPPLYWater Science & Technology, 1994
- Explanation of Biological Meaning of the So/Xo Ratio in Batch CultivationWater Science & Technology, 1992
- BIO-DENITRO and BIO-DENIPHO Systems – Experiences and Advanced Model Development: The Danish Systems for Biological N and P RemovalWater Science & Technology, 1989
- The dynamics of microbial growth on soluble substratesWater Research, 1982