Behavioral and autonomic thermoregulation in mice exposed to microwave radiation
- 1 October 1983
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 55 (4) , 1242-1248
- https://doi.org/10.1152/jappl.1983.55.4.1242
Abstract
Preferred ambient temperature (Ta) and breathing rate were measured in free-moving mice exposed to 2,450-MHz microwaves. A waveguide-exposure system was imposed with a longitudinal temperature gradient that permitted mice to select their preferred Ta. Breathing rate was determined by analyzing the rhythmic shifts in microwave energy not absorbed by the animal. Without microwave exposure mice selected an average Ta of 31 degrees C. This preferred Ta did not change until the specific absorption rate (SAR) at 2,450 MHz exceeded approximately 7.0 W X kg-1. Mice maintained their breathing rate near baseline levels by selecting a cooler Ta during microwave exposure. In contrast, mice maintained at 31 degrees C underwent a sharp increase in breathing rate when SAR exceeded approximately 7.0 W X kg-1. Mice exposed to microwaves in a waveguide with a temperature gradient increased breathing rate 0.6 breaths/min per unit increase in SAR, whereas without the temperature gradient breathing rate increased by 9.6 breaths/min per unit increase in SAR. Data from this study support previous studies that have shown behavioral thermoregulation is more effective (or efficient) in minimizing a thermal load than autonomic thermoregulation.This publication has 0 references indexed in Scilit: