Diathermy Hook Ablation of Posterior Urethral Valves in Neonates and Infants
- 1 December 1988
- journal article
- research article
- Published by Wiley in British Journal of Urology
- Vol. 62 (6) , 593-594
- https://doi.org/10.1111/j.1464-410x.1988.tb04433.x
Abstract
An insulated diathermy hook was used to destroy the posterior urethral valve in 10 boys. The technique needs no anaesthetic, no endoscopic equipment, no perineal urethrostomy and only occasional catheter drainage of the bladder. It is performed in the x-ray department, where the efficacy of the procedure can be checked immediately with a further cystogram. The results are compared with those in 7 other boys whose valves were destroyed by conventional endoscopic means.This publication has 4 references indexed in Scilit:
- Neodymium:Yag Laser Ablation of Posterior Urethral ValvesJournal of Urology, 1987
- An Improved Hook for Destroying Posterior Urethral ValvesJournal of Urology, 1986
- An Antegrade Technique for Ablation of Posterior Urethral ValvesJournal of Urology, 1984
- Urethral Valves1British Journal of Urology, 1973