A new actigraph for long-term registration of the duration and intensity of tremor and movement
- 1 March 1998
- journal article
- clinical trial
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 45 (3) , 386-395
- https://doi.org/10.1109/10.661163
Abstract
Actigraphy, the long-term measurement of human movement with a small solid state recorder, is gaining acceptance as a useful method in many research fields. Currently available actigraphs assess or estimate the movement duration per time interval. However, the output gives no information on movement type or intensity, and cannot be used in subjects suffering from tremor. The present paper describes a new type of actigraph, that has been developed primarily for the long-term evaluation of motor symptoms in Parkinson patients. The device is the first to discriminate tremor from other movements and to assess both duration and intensity of the two types of movement. It is based on a Motorola 68HC805B6 microcontroller and contains: an accelerometer, programmable gain stages, programmable low- and highpass filters, a programmable level comparator, a peak detector, interface circuits, a real time clock, data storage, and control circuitry. The micro-controller performs a period amplitude sequence analysis (PASA) on the conditioned accelerometer signal, and stores four output variables (tremor duration, tremor amplitude, movement duration, and movement amplitude) at the end of programmable time intervals. The analysis of fluctuations in the motor symptoms of, e.g., Parkinson patients using this actigraph can be of great help in the pharmacological management of symptoms.Keywords
This publication has 11 references indexed in Scilit:
- Circadian rest—activity rhythm disturbances in alzheimer's diseaseBiological Psychiatry, 1996
- Gravitational artefact in frequency spectra of movement acceleration: implications for actigraphy in young and elderly subjectsJournal of Neuroscience Methods, 1996
- Ambulatory monitoring of tremor and other movements before and after thalamotomy: A new quantitative techniqueJournal of the Neurological Sciences, 1993
- 24 Hour continuous tremor quantification based on EMG recordingElectroencephalography and Clinical Neurophysiology, 1989
- Twenty-four-hour tremor recordings in the evaluation of the treatment of Parkinson's diseaseZeitschrift für Neurologie, 1988
- Observations on the design and specification of a wrist-worn human activity monitoring systemBehavior Research Methods, Instruments & Computers, 1985
- A new ambulatory monitoring system for tremorElectroencephalography and Clinical Neurophysiology, 1983
- Quantitative Evaluation of Long-Term Parkinson TremorIEEE Transactions on Biomedical Engineering, 1977
- ParkinsonismNeurology, 1967
- A practical method of designing RC active filtersIRE Transactions on Circuit Theory, 1955