Effect of fiber optic probe geometry on depth-resolved fluorescence measurements from epithelial tissues: a Monte Carlo simulation
- 1 January 2003
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 8 (2) , 237-247
- https://doi.org/10.1117/1.1559058
Abstract
Developing fiber optic probe geometries to selectively measure fluorescence spectra from different sublayers within human epithelial tissues will potentially improve the endogenous fluorescence contrast between neoplastic and nonneoplastic tissues. In this study, two basic fiber optic probe geometries, which are called the variable aperture (VA) and multidistance (MD) approaches, are compared for depth-resolved fluorescence measurements from human cervical epithelial tissues. The VA probe has completely overlapping illumination and collection areas with variable diameters, while the MD probe employs separate illumination and collection fibers with a fixed separation between them. Monte Carlo simulation results show that the total fluorescence detected is significantly higher for the VA probe geometry, while the probing depth is significantly greater for the MD probe geometry. An important observation is that the VA probe is more sensitive to the epithelial layer, while the MD probe is more sensitive to the stromal layer. The effect of other factors, including numerical aperture (NA) and tissue optical properties on the fluorescence measurements with VA and MD probe geometries, are also evaluated. The total fluorescence detected with both probe geometries significantly increases when the fiber NA is changed from 0.22 to 0.37. The sensitivity to different sublayers is found to be strongly dependent on the tissue optical properties. The simulation results are used to design a simple fiber optic probe that combines both the VA and MD geometries to enable fluorescence measurements from the different sublayers within human epithelial tissues. © 2003 Society of Photo-Optical Instrumentation Engineers.Keywords
This publication has 25 references indexed in Scilit:
- Realistic three-dimensional epithelial tissue phantoms for biomedical opticsJournal of Biomedical Optics, 2002
- Autofluorescence characteristics of immortalized and carcinogen-transformed human bronchial epithelial cellsJournal of Biomedical Optics, 2001
- Characterization of the Autofluorescence of Polymorphonuclear Leukocytes, Mononuclear Leukocytes and Cervical Epithelial Cancer Cells for Improved Spectroscopic Discrimination of Inflammation from DysplasiaPhotochemistry and Photobiology, 2000
- Fluorescence Spectroscopy of Neoplastic and Non-Neoplastic TissuesNeoplasia, 2000
- Autofluorescence Patterns in Short-Term Cultures of Normal Cervical TissuePhotochemistry and Photobiology, 2000
- The Histological Basis of Detection of Adenoma and Cancer in the Colon by Autofluorescence Endoscopic ImagingEndoscopy, 1999
- In Vivo Fluorescence Spectroscopy and Imaging for Oncological ApplicationsPhotochemistry and Photobiology, 1998
- QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSISAnnual Review of Physical Chemistry, 1996
- Laser-induced fluorescence spectroscopy at endoscopy: tissue optics, Monte Carlo modeling, and in vivo measurementsOptical Engineering, 1995
- Spectral diagnosis of atherosclerosis using an optical fiber laser catheterAmerican Heart Journal, 1989