Microfluidic biosensing systems : Part I. Development and optimisation of enzymatic chemiluminescent µ-biosensors based on silicon microchips
- 14 September 2004
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 4 (5) , 481-487
- https://doi.org/10.1039/b400894d
Abstract
Chemiluminescent (CL) enzyme-based flow-through microchip biosensors (µ-biosensors) for detection of glucose and ethanol were developed for the purpose of monitoring real-time production and release of glucose and ethanol from microchip immobilised yeast cells. Part I of this study focuses on the development and optimisation of the µ-biosensors in a microfluidic sequential injection analysis (µSIA) system. Glucose oxidase (GOX) or alcohol oxidase (AOX) was co-immobilised with horseradish peroxidase (HRP) on porous silicon flow through microchips. The hydrogen peroxide produced from oxidation of the corresponding analyte (glucose or ethanol) took part in the chemiluminescent (CL) oxidation of luminol catalysed by HRP enhanced by addition of p-iodophenol (PIP). All steps in the µSIA system, including control of syringe pump, multiposition valve (MPV) and data readout, were computer controlled. The influence of flow rate and luminol- and PIP concentration were investigated using a 23-factor experiment using the GOX-HRP sensor. It was found that all estimated single factors and the highest order of interaction were significant. The optimum was found at 250 µM luminol and 150 µM PIP at a flow rate of 18 µl min−1, the latter as a compromise between signal intensity and analysis time. Using the optimised system settings one sample was processed within 5 min. Two different immobilisation chemistries were investigated for both µ-biosensors based on 3-aminopropyltriethoxsilane (APTS)- or polyethylenimine (PEI) functionalisation followed by glutaraldehyde (GA) activation. GOX-HRP µ-biosensors responded linear in a log–log format within the range 10–1000 µM glucose. Both had an operational stability of at least 8 days, but the PEI-GOX-HRP sensor was more sensitive. The AOX-HRP µ-biosensors responded linear (log–log) in the range between 1 and 10 mM ethanol, but the PEI-AOX-HRP sensor was in general more sensitive. Both sensors had an operational stability of at least 8 h, but with a half-life of 2–3 days.Keywords
This publication has 45 references indexed in Scilit:
- Microfluidic devices for cellomics: a reviewPublished by Elsevier ,2003
- Chemiluminescence multichannel immunosensor for biodetectionAnalytica Chimica Acta, 2002
- Getting started with yeastPublished by Elsevier ,2002
- On-chip generation and detection of electrochemiluminescenceAnalytica Chimica Acta, 1998
- Alcohol biosensors based on coupled oxidase-peroxidase systemsAnalytica Chimica Acta, 1996
- Selective flow-injection determination of methanol using immobilized enzyme reactorsAnalytica Chimica Acta, 1995
- Selective flow-injection determination of methanol in the presence of ethanol based on a multi-enzyme system with chemiluminescence detectionAnalytica Chimica Acta, 1993
- Flow-injection determination of ethanol by fiber-optic chemiluminescence measurementAnalytica Chimica Acta, 1992
- Sequential injection: a new concept for chemical sensors, process analysis and laboratory assaysAnalytica Chimica Acta, 1990
- Determination of hydrogen peroxide in a flow system with microperoxidase as catalyst for the luminol chemiluminescence reactionAnalytica Chimica Acta, 1982