Abstract
Purpose: Demonstrate noninvasive imaging methods for in vivo characterization of cardiac structure and function in mice using a micro-CT system that provides high photon fluence rate and integrated motion control. Materials and Methods: Simultaneous cardiac- and respiratory-gated micro-CT was performed in C57BL/6 mice during constant intravenous infusion of a conventional iodinated contrast agent (Isovue-370), and after a single intravenous injection of a blood pool contrast agent (Fenestra VC). Multiple phases of the cardiac cycle were reconstructed with contrast to noise and spatial resolution sufficient for quantitative assessment of cardiac function. Results: Contrast enhancement with Isovue-370 increased over time with a maximum of ~500 HU (aorta) and 900 HU (kidney cortex). Fenestra VC provided more constant enhancement over 3 hr, with maximum enhancement of ~620 HU (aorta) and ~90 HU (kidney cortex). The maximum enhancement difference between blood and myocardium in the heart was ~250 HU for Isovue-370 and ~500 HU for Fenestra VC. In mice with Fenestra VC, volumetric measurements of the left ventricle were performed and cardiac function was estimated by ejection fraction, stroke volume, and cardiac output. Conclusion: Image quality with Fenestra VC was sufficient for morphological and functional studies required for a standardized method of cardiac phenotyping of the mouse.Keywords
This publication has 24 references indexed in Scilit:
- Effects of breathing and cardiac motion on spatial resolution in the microscopic imaging of rodentsMagnetic Resonance in Medicine, 2005
- Micro‐CT with respiratory and cardiac gatingMedical Physics, 2004
- Cardiac PET imaging of blood flow, metabolism, and function in normal and infarcted ratsIEEE Transactions on Nuclear Science, 2004
- Geometric studies on variable radius spiral cone‐beam scanningMedical Physics, 2004
- Fundamental image quality limits for microcomputed tomography in small animalsMedical Physics, 2003
- High‐resolution MRI with cardiac and respiratory gating allows for accurate in vivo atherosclerotic plaque visualization in the murine aortic archMagnetic Resonance in Medicine, 2003
- Micro-CT in small animal and specimen imagingTrends in Biotechnology, 2002
- MR microscopy of the rat lung using projection reconstructionMagnetic Resonance in Medicine, 1993
- Computed tomography of the heart: Evaluation of anatomy and functionJournal of the American College of Cardiology, 1985
- The Sensitivity Performance of the Human Eye on an Absolute Scale*Journal of the Optical Society of America, 1948