Wall Mechanics of the Stented Rabbit Aorta: Long-Term Study and Correlation with Histological Findings
- 1 June 2003
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 10 (3) , 577-584
- https://doi.org/10.1177/152660280301000325
Abstract
Purpose: To evaluate long-term changes in arterial wall mechanics induced by stenting of the rabbit aorta. Methods: Eighteen New Zealand white rabbits had initial stent deployment (3×8 mm Multilink) at 110% of the pre-stenting abdominal aortic diameter. Group A (n=10) had no post-deployment stent expansion and group B (n=8) had 30% overdilation of the stent. A noninvasive B-mode ultrasound examination coupled with image processing allowed measurement of diameters at systole and diastole and the calculation of diameter compliance. Measurements were performed before stenting and compared to those recorded immediately after stenting and at 3 months at 3 locations: upstream from the stent, at the stent level, and downstream from the stent. Measurements were also compared among measurement sites. The pathological study included measurement of intimal thickening and calculation of an injury score. Results: At the stent level, diameter compliance was significantly lower after initial stenting and at 3 months than before stenting (group A: p<0.005; group B: p<0.001) and than downstream or upstream from the stent (group A: p<0.0001, group B: p<0.005). No significant difference in diameter compliance was found between groups A and B. In group B, intimal thickening and the injury score were greater than in group A (p<0.05 and p<0.0001, respectively). Conclusions: Endovascular stenting of the rabbit aorta impairs wall mechanics. Performing 30% overdilation of the stent does not worsen this impairment but induces greater in-stent intimal hyperplasia.Keywords
This publication has 26 references indexed in Scilit:
- Resource utilization and clinical outcomes of coronary stenting: A comparison of intravascular ultrasound and angiographical guided stent implantationAmerican Heart Journal, 2001
- Changes in Wall Mechanics After Endovascular Stenting in the Rabbit AortaAmerican Journal of Roentgenology, 2001
- The comparative pathobiology of atherosclerosis and restenosisThe American Journal of Cardiology, 2000
- Hemodynamics and Wall Mechanics after Stent Placement in Swine Iliac Arteries: Comparative Results from Six Stent DesignsRadiology, 1999
- Balloon-Artery Interactions During Stent PlacementCirculation Research, 1999
- Pathology of Acute and Chronic Coronary Stenting in HumansCirculation, 1999
- Stenting of Nonacute Total Coronary Occlusions: Predictors of Late Angiographic OutcomeJournal of the American College of Cardiology, 1998
- A Randomized Comparison of Coronary-Stent Placement and Balloon Angioplasty in the Treatment of Coronary Artery DiseaseNew England Journal of Medicine, 1994
- The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting.Circulation, 1992
- Restenosis and the proportional neointimal response to coronary artery injury: Results in a porcine modelJournal of the American College of Cardiology, 1992