Scale-space signatures for the detection of clustered microcalcifications in digital mammograms
- 1 January 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 18 (9) , 774-786
- https://doi.org/10.1109/42.802755
Abstract
A method is described for the automated detection of microcalcifications in digitized mammograms. The method is based on the Laplacian scale-space representation of the mammogram only. First, possible locations of microcalcifications are identified as local maxima in the filtered image on a range of scales. For each finding, the size and local contrast is estimated, based on the Laplacian response denoted as the scale-space signature. A finding is marked as a microcalcification if the estimated contrast is larger than a predefined threshold which depends on the size of the finding. It is shown that the signature has a characteristic peak, revealing the corresponding image features. This peak can be robustly determined. The basic method is significantly improved by consideration of the statistical variation of the estimated contrast, which is the result of the complex noise characteristic of the mammograms. The method is evaluated with the Nijmegen database and compared to other methods using these mammograms. Results are presented as the free-response receiver operating characteristic (FROC) performance. At a rate of one false positive cluster per image the method reaches a sensitivity of 0.84, which is comparable to the best results achieved so far.Keywords
This publication has 27 references indexed in Scilit:
- Mammographic-Pathological CorrelationsPublished by Springer Nature ,2000
- Microcalcifications Detection Using Adaptive Filtering and Gaussianity TestsPublished by Springer Nature ,1998
- Detection of Microcalcification Clusters in Digital Mammography Via the Spatial Scan Statistic with Stochastic Scan PartitionsPublished by Springer Nature ,1998
- Wavelet transforms for detecting microcalcifications in mammogramsIEEE Transactions on Medical Imaging, 1996
- Image feature analysis and computer-aided diagnosis in mammography: Reduction of false-positive clustered microcalcifications using local edge-gradient analysisMedical Physics, 1995
- Digitization requirements in mammography: Effects on computer‐aided detection of microcalcificationsMedical Physics, 1994
- ADAPTIVE NOISE EQUALIZATION AND RECOGNITION OF MICROCALCIFICATION CLUSTERS IN MAMMOGRAMSInternational Journal of Pattern Recognition and Artificial Intelligence, 1993
- Computer-aided detection of clustered microcalcifications: An improved method for grouping detected signalsMedical Physics, 1993
- Iso-precision scaling of digitized mammograms to facilitate image analysisPublished by SPIE-Intl Soc Optical Eng ,1991
- Image feature analysis and computer-aided diagnosis in digital radiography. I. Automated detection of microcalcifications in mammographyMedical Physics, 1987