Functional MRI of the rodent somatosensory pathway using multislice echo planar imaging
Open Access
- 28 June 2004
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 52 (1) , 89-99
- https://doi.org/10.1002/mrm.20114
Abstract
A multislice EPI sequence was used to obtain functional MR images of the entire rat brain with BOLD contrast at 11.7 T. Ten to 11 slices covering the rat brain, with an in-plane resolution of 300 μm, provided enough sensitivity to detect activation in brain regions known to be involved in the somatosensory pathway during stimulation of the forelimbs. These regions were identified by warping a digitized rat brain atlas to each set of images. Data analysis was constrained to four major areas of the somatosensory pathway: primary and secondary somatosensory cortices, thalamus, and cerebellum. Incidence maps were generated. Electrical stimulation at 3 Hz led to significant activation in the primary sensory cortex in all rats. Activation in the secondary sensory cortex and cerebellum was observed in 70% of the studies, while thalamic activation was observed in 40%. The amplitude of activation was measured for each area, and average response time courses were calculated. Finally, the frequency dependence of the response to forepaw stimulation was measured in each of the activated areas. Optimal activation occurred in all areas at 3 Hz. These results demonstrate that whole-brain fMRI can be performed on rodents at 11.7 T to probe a well-defined neural network. Magn Reson Med 52:89–99, 2004. Published 2004 Wiley-Liss, Inc.Keywords
This publication has 39 references indexed in Scilit:
- Application of sensitivity‐encoded echo‐planar imaging for blood oxygen level‐dependent functional brain imaging †Magnetic Resonance in Medicine, 2002
- Mapping at glomerular resolution: fMRI of rat olfactory bulbMagnetic Resonance in Medicine, 2002
- Design of a SENSE‐optimized high‐sensitivity MRI receive coil for brain imagingMagnetic Resonance in Medicine, 2002
- Functional MRI at 4.7 Tesla of the Rat Brain during Electric Stimulation of Forepaw, Hindpaw, or Tail in Single- and Multislice ExperimentsExperimental Neurology, 2000
- High-Resolution CMRO2 Mapping in Rat Cortex: A Multiparametric Approach to Calibration of BOLD Image Contrast at 7 TeslaJournal of Cerebral Blood Flow & Metabolism, 2000
- Early Temporal Characteristics of Cerebral Blood Flow and Deoxyhemoglobin Changes during Somatosensory StimulationJournal of Cerebral Blood Flow & Metabolism, 2000
- Simultaneous Blood Oxygenation Level-Dependent and Cerebral Blood Flow Functional Magnetic Resonance Imaging during Forepaw Stimulation in the RatJournal of Cerebral Blood Flow & Metabolism, 1999
- The Effect of Slice Order and Thickness on fMRI Activation Data Using Multislice Echo-Planar ImagingNeuroImage, 1999
- Variation of functional MRI signal in response to frequency of somatosensory stimulation in α‐chloralose anesthetized ratsMagnetic Resonance in Medicine, 1996
- Multislice interleaved excitation cycles (MUSIC): An efficient gradient‐echo technique for functional MRIMagnetic Resonance in Medicine, 1996