Membrane curing of concrete: water vapour permeability of curing membranes
- 1 December 1989
- journal article
- Published by Thomas Telford Ltd. in Magazine of Concrete Research
- Vol. 41 (149) , 221-228
- https://doi.org/10.1680/macr.1989.41.149.221
Abstract
This Paper describes the developmental work undertaken to enable the measurement of the water vapour permeability of a curing membrane and shows that a single-cell transmission test method which is inexpensive, versatile andeasy to operate can be usede effectively for this purpose. The water vapour permeability of a curing menzbrane determines that mernbrane's intrinsic moisture retention characteristic and is shown to provide a more reliable peyformance indicator for membrane curing of concrete than the commonlJ1 used curing efficiency index, which is an empirical and relative value that depends on a particular test method and measuring system.Keywords
This publication has 0 references indexed in Scilit: