The simplicity of cobalt units gives them the advantage of reduced maintenance, running costs and downtime when compared with linear accelerators. However, treatments carried out on such units are typically limited to simple techniques. This study has explored the use of cobalt beams for conformal and intensity-modulated radiotherapy (IMRT). Six patients, covering a range of treatment sites, were planned using both X-ray photons (6/10 MV) and cobalt-60 gamma rays (1.17 and 1.33 MeV). A range of conformal and IMRT techniques were considered, as appropriate. Conformal plans created using cobalt beams for small breast, meningioma and parotid cases were found to compare well with those created using X-ray photons. By using additional fields, acceptable conformal plans were also created for oesophagus and prostate cases. IMRT plans were found to be of comparable quality for meningioma, parotid and thyroid cases on the basis of dose-volume histogram analysis. We conclude that it is possible to plan high-quality radical radiotherapy treatments for cobalt units. A well-designed beam blocking/compensation system would be required to enable a practical and efficient alternative to multileaf collimator (MLC)-based linac treatments to be offered. If cobalt units were to have such features incorporated into them, they could offer considerable benefits to the radiotherapy community.Keywords
This publication has 12 references indexed in Scilit:
- What is the optimum breast plan: a study based on the START trial plansThe British Journal of Radiology, 2006
- Multinational assessment of some operational costs of teletherapyRadiotherapy and Oncology, 2004
- Clinical implementation of dynamic and step-and-shoot IMRT to treat prostate cancer with high risk of pelvic lymph node involvementRadiotherapy and Oncology, 2004
- A multiportal compensator system for IMRT deliveryMedical Physics, 2003
- MAINTENANCE COSTS FOR COBALT MACHINES AND LINEAR ACCELERATORS: NEW MACHINES VERSUS OLDRadiotherapy and Oncology, 2002
- Optimisation of radiotherapy for carcinoma of the parotid gland: a comparison of conventional, three-dimensional conformal, and intensity-modulated techniquesRadiotherapy and Oncology, 2001
- Improvements in target coverage and reduced spinal cord irradiation using intensity-modulated radiotherapy (IMRT) in patients with carcinoma of the thyroid glandRadiotherapy and Oncology, 2001
- A pencil beam model for photon dose calculationMedical Physics, 1992
- Tolerance of normal tissue to therapeutic irradiationPublished by Elsevier ,1991