Nuclear magnetic resonance hahn spin‐echo decay (T2) in live rats with endotoxin lung injury
- 1 April 1993
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 29 (4) , 441-445
- https://doi.org/10.1002/mrm.1910290404
Abstract
To determine the possibility of using nuclear magnetic resonance imaging to study experimentally induced lung injury, we measured in the lungs of spontaneously breathing living rats the time course of both the Hahn spin‐echo decay (T2) and the proton density after endotoxin injury. In order to minimize artifacts arising from motions of the nearby chest wall and heart, we used a motion‐insensitive technique (the interleaved line scan). A typical Hahn T2 measurement was obtained over a region of interest from a series of images each with a different echo time, which ranged from 16 to 110 ms. Lung water content was determined by integrating the proton density over the region of interest. The Hahn T2 and proton density were measured before and at 1, 3, 6, and 9 h after intravenous injection of endotoxin. The effects of the treatment administered before and after endotoxin injection were also evaluated. Endotoxin treatment caused lengthening of both fast (T2f) and slow (T2s) Hahn T2 components but had no significant effect on the proton density, consistent with the notion that endotoxin causes lung injury without significant lung water accumulation in rats. However, the methylprednisolone treatment prevented the lengthening of T2s but did not seem to have a significant effect on T2f. Our results suggest that NMR imaging can be used to detect and monitor experimental lung injury in intact living animals, even in the absence of variations of lung water content.Keywords
This publication has 26 references indexed in Scilit:
- Comparison of in Vivo and in vitro Hahn T2 measurements in rat lungMagnetic Resonance in Medicine, 1992
- An in vivo NMR imaging determination of multiexponential Hahn T2 of normal lungMagnetic Resonance in Medicine, 1990
- T2 of endotoxin lung injury with and without methylprednisolone treatmentMagnetic Resonance in Medicine, 1990
- Non-Brownian water self-diffusion in lung tissueMagnetic Resonance in Medicine, 1988
- A Controlled Clinical Trial of High-Dose Methylprednisolone in the Treatment of Severe Sepsis and Septic ShockNew England Journal of Medicine, 1987
- A mathematical model of diamagnetic line broadening in lung tissue and similar heterogeneous systems: Calculations and measurementsJournal of Magnetic Resonance (1969), 1987
- An efficient, highly homogeneous radiofrequency coil for whole-body NMR imaging at 1.5 TJournal of Magnetic Resonance (1969), 1985
- The Effect of Pulmonary Edema on Proton Nuclear Magnetic Resonance Relaxation TimesInvestigative Radiology, 1984
- Spin warp NMR imaging and applications to human whole-body imagingPhysics in Medicine & Biology, 1980
- Effects of Diffusion on Free Precession in Nuclear Magnetic Resonance ExperimentsPhysical Review B, 1954