System for mechanical measurements during cardiopulmonary resuscitation in humans
- 1 January 1990
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 37 (2) , 204-210
- https://doi.org/10.1109/10.46261
Abstract
Effective study of CPR requires measurement of the mechanical properties of the human chest and the resultant vascular pressures. A computer-based mobile data acquisition system was designed and built for this purpose. During manual CPR a short cylindrical module was placed between the rescuer's hands and the patient's chest. This module, which was attached to an easily manipulated position-sensing arm, measured force and acceleration at the sternum. Three-dimensional position and orientation of the module were measured, as well as the component of the applied force which was perpendicular to the sternum. The central venous and aortic pressures were measured by high fidelity pressure transducers. All transducer signals were recorded by digital computer. Real-time feedback of sternal force and displacement, and vascular pressures was provided to the rescue team via chart recordings. An audible signal was produced as an aid in maintaining desired compression rate and duration. The system's mobility permitted rapid implementation at any hospital location. In conclusion, this system was capable of measuring, recording, and displaying multiple physical quantities during manual CPR in humans.Keywords
This publication has 13 references indexed in Scilit:
- Identification of dynamic mechanical parameters of the human chest during manual cadiopulmonary resuscitationIEEE Transactions on Biomedical Engineering, 1990
- Chest wall acceleration and force measurements in simulated manual and mechanical cardiopulmonary resuscitationCritical Care Medicine, 1988
- Intrathoracic pressure fluctuations move blood during CPR: Comparison of hemodynamic data with predictions from a mathematical modelAnnals of Biomedical Engineering, 1987
- Determinants of blood flow to vital organs during cardiopulmonary resuscitation in dogs.Circulation, 1986
- Elastic properties of the human chest during cardiopulmonary resuscitationCritical Care Medicine, 1983
- Pressure-synchronized cineangiography during experimental cardiopulmonary resuscitation.Circulation, 1981
- Mechanisms of blood flow during cardiopulmonary resuscitation.Circulation, 1980
- Bystander-Initiated Cardiopulmonary Resuscitation in the Management of Ventricular FibrillationAnnals of Internal Medicine, 1979
- HÆMODYNAMIC EFFECTS OF EXTERNAL CARDIAC COMPRESSIONThe Lancet, 1964
- THE EFFICIENCY OF CARDIAC MASSAGEThe Lancet, 1962