Assessment of Dialysis Dose by Measured Clearance versus Extrapolated Data
Open Access
- 1 July 1993
- journal article
- research article
- Published by SAGE Publications in Peritoneal Dialysis International
- Vol. 13 (3) , 184-188
- https://doi.org/10.1177/089686089301300304
Abstract
Objective: To determine whether estimates of daily dialysis clearance of creatinine and urea, based on data from the 4-hour peritoneal equilibration test, correlate well with daily dialysis clearance measured by 24-hour dialysate collection in chronic ambulatory peritoneal dialysis patients. Design: Prospective study in which each subject collected all dialysate from a 24-hour period and then immediately thereafter underwent a standard peritoneal equilibration test (PET). Daily clearances of creatinine and urea were calculated from 24-hour dialysate collections by standard methods and then were compared with several estimates of 24-hour clearance based on PET data. Setting: Single peritoneal dialysis unit of a university teaching hospital. Patients: Thirty-six stable patients on continuous ambulatory peritoneal dialysis (CAPD). Main Outcome: The estimated values for daily dialysis clearance both overestimated and underestimated the measured 24-hour clearance. The correlation coefficient between the extrapolations and the actual 24-hour clearances ranged from 0.63–0.68. The range of discordance for daily creatinine clearance was from -2530 mL/dayto +2199 mL/day. For daily urea clearance, the range of discordance was from -21 03 mL/ day to +1940 mL/day. The peritoneal membrane transport characteristics of the individual patient did not predict whether the extrapolation overestimated orunder estimated the measured daily clearance. Conclusion: Extrapolation of PET data is not a reliable method to estimate the dose of dialysis delivered to the patient. A 24-hour collection of dialysis is necessary for this determination.Keywords
This publication has 20 references indexed in Scilit:
- Quantitating Peritoneal Dialysis Delivery: A Required Standard of CareSeminars in Dialysis, 2007
- Adequacy of Peritoneal Dialysis and Other Outcome-Related Risk Factors: A Critical AppraisalSeminars in Dialysis, 2007
- Lack of correlation between urea kinetic indices and clinical outcomes in CAPD patientsKidney International, 1991
- Adequacy of Peritoneal DialysisSeminars in Dialysis, 1990
- Clinical Value of Standardized Equilibration Tests in CAPD PatientsBlood Purification, 1989
- Contribution of lymphatic absorption to loss of ultrafiltration and solute clearances in continuous ambulatory peritoneal dialysis.Journal of Clinical Investigation, 1987
- Effect of the Hemodialysis Prescription on Patient MorbidityNew England Journal of Medicine, 1981
- Three exchanges with a 2.5-liter volume for continuous ambulatory peritoneal dialysisKidney International, 1981
- Follow-up of peritoneal clearances in patients undergoing continuous ambulatory peritoneal dialysisKidney International, 1979
- Sequential Clearance and Dialysance Measurements in Chronic Peritoneal Dialysis PatientsNephron, 1977