Cardiac Dyssynchrony Analysis Using Circumferential Versus Longitudinal Strain
- 31 May 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Circulation
- Vol. 111 (21) , 2760-2767
- https://doi.org/10.1161/circulationaha.104.508457
Abstract
Background— QRS duration is commonly used to select heart failure patients for cardiac resynchronization therapy (CRT). However, not all patients respond to CRT, and recent data suggest that direct assessments of mechanical dyssynchrony may better predict chronic response. Echo-Doppler methods are being used increasingly, but these principally rely on longitudinal motion (ε ll ). It is unknown whether this analysis yields qualitative and/or quantitative results similar to those based on motion in the predominant muscle-fiber orientation (circumferential; ε cc ). Methods and Results— Both ε ll and ε cc strains were calculated throughout the left ventricle from 3D MR-tagged images for the full cardiac cycle in dogs with cardiac failure and a left bundle conduction delay. Dyssynchrony was assessed from both temporal and regional strain variance analysis. CRT implemented by either biventricular (BiV) or left ventricular–only (LV) pacing enhanced systolic function similarly and correlated with improved dyssynchrony based on ε cc -based metrics. In contrast, longitudinal-based analyses revealed significant resynchronization with BiV but not LV for the overall cycle and correlated poorly with global functional benefit. Furthermore, unlike circumferential analysis, ε ll -based indexes indicated resynchronization in diastole but much less in systole and had a lower dynamic range and higher intrasubject variance. Conclusions— Dyssynchrony assessed by longitudinal motion is less sensitive to dyssynchrony, follows different time courses than those from circumferential motion, and may manifest CRT benefit during specific cardiac phases depending on pacing mode. These results highlight potential limitations to ε ll -based analyses and support further efforts to develop noninvasive synchrony measures based on circumferential deformation.Keywords
This publication has 41 references indexed in Scilit:
- Interventricular and intraventricular dyssynchrony in idiopathic dilated cardiomyopathyJournal of the American College of Cardiology, 2002
- Cardiac resynchronization therapy tailored by echocardiographic evaluation of ventricular asynchronyJournal of the American College of Cardiology, 2002
- Systolic Improvement and Mechanical Resynchronization Does Not Require Electrical Synchrony in the Dilated Failing Heart With Left Bundle-Branch BlockCirculation, 2002
- Interference in Implanted Cardiac Devices, Part IIPacing and Clinical Electrophysiology, 2002
- Tissue doppler imaging predicts improved systolic performance and reversed left ventricular remodeling during long-term cardiac resynchronization therapyJournal of the American College of Cardiology, 2002
- Echocardiographic quantification of left ventricular asynchrony predicts an acute hemodynamic benefit of cardiac resynchronization therapyJournal of the American College of Cardiology, 2002
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002
- Quantitation of basal dyssynchrony and acute resynchronization from left or biventricular pacing by novel echo-contrast variability imagingJournal of the American College of Cardiology, 2002
- Tissue Doppler Echocardiographic Evidence of Reverse Remodeling and Improved Synchronicity by Simultaneously Delaying Regional Contraction After Biventricular Pacing Therapy in Heart FailureCirculation, 2002
- Echocardiographic prediction of long-term response to biventricular pacemaker in severe heart failure.European Journal of Heart Failure, 2002