Pulsed Wave Doppler Measurement of Cardiac Output from the Right Ventricular Outflow Tract
- 1 September 1996
- journal article
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 83 (3) , 466-471
- https://doi.org/10.1213/00000539-199609000-00004
Abstract
Doppler ultrasound can be used to measure cardiac output (CO).Intraoperative Doppler cardiac output (DCO) by transesophageal echocardiography (TEE) has been studied using blood flow velocity from the left ventricular outflow tract (LVOT), the mitral valve (MV), and the main pulmonary artery (MPA). The purpose of this study was to compare DCO, measured from a relatively new TEE view of the right ventricular outflow tract (RVOT), with thermodilution cardiac output (TDCO). We also compared changes in DCO from the RVOT to changes in TDCO. A 5.0/3.7 MHz multiplane TEE probe was placed in 45 adult cardiac surgical patients undergoing general anesthesia. Patients were excluded if there was greater than mild tricuspid valve insufficiency. From the transgastric view, at approximately 110-140 degrees, the RVOT was imaged. DCO was calculated from 1) the time-velocity integral (TVI) using pulse wave (PW) Doppler, 2) the area of the RVOT (measured in early systole using the diameter (pi (D/2)2) of the RVOT at the level of the PW Doppler sample volume), and 3) the heart rate. Simultaneous TDCO was performed by a separate examiner. The RVOT was imaged satisfactorily in 84% of patients (38/45). The mean bias between DCO and TDCO was -0.01 L/min (2 SD +/- 0.45 L/min; n = 38). There was good correlation between DCO and TDCO (R2 = 0.97). Changes in TDCO and changes in DCO were compared in 15 patients. The mean bias between changes in DCO and changes in TDCO was 0.04 L/min (2 SD +/- 0.66 L/min). Analysis of the changes in DCO and TDCO showed good correlation (R2 = 0.96). We conclude that there is a good correlation between DCO measured from the RVOT and TDCO. This technique permits cardiac output measurement without the necessity of placing a pulmonary artery catheter, and it also provides a method of evaluating RVOT blood flow. (Anesth Analg 1996;83:466-71)Keywords
This publication has 22 references indexed in Scilit:
- Transesophageal transgastric echocardiography in infants and children: The subcostal view equivalentJournal of the American Society of Echocardiography, 1995
- Transgastric continuous-wave Doppler to determine cardiac outputThe American Journal of Cardiology, 1993
- Intraoperative Echocardiography for Evaluation of Congenital Heart Defects in Infants and ChildrenAnesthesiology, 1992
- Measurement of Pulmonary Blood Flow with Transesophageal Two-dimensional and Doppler EchocardiographyAnesthesiology, 1991
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986
- Variable effects of changes in flow rate through the aortic, pulmonary and mitral valves on valve area and flow velocity: Impact on quantitative doppler flow calculationsJournal of the American College of Cardiology, 1985
- Doppler Echocardiography: Theory, Instrumentation, Technique, and ApplicationMayo Clinic Proceedings, 1985
- Pulsed Doppler echocardiographic determination of stroke volume and cardiac output: clinical validation of two new methods using the apical window.Circulation, 1984
- Some aspects of the clinical use of thermodilution in measuring cardiac output: With particular reference to the Swan-Ganz thermodilution cathetersScandinavian Journal of Clinical and Laboratory Investigation, 1978
- Validity of thermodilution method for measurement of cardiac output in pulmonary oedemaCardiovascular Research, 1973