An advanced demultiplexing system for physiological stimulation
- 1 January 1997
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 44 (12) , 1210-1220
- https://doi.org/10.1109/10.649992
Abstract
A CMOS very large scale integration (VLSI) chip has been designed and built to implement a scheme developed for multiplexing/demultiplexing the signals required to operate an intracortical stimulating electrode array. Because the use of radio telemetry in a proposed system utilizing this chip may impose limits upon the rate of data transmission to the chip, the scheme described herein was used to reduce the amount of digital information which must be sent to control a large quantity (up to several hundred) of stimulating electrodes. By incorporating multiple current sources on chip, many channels may be stimulated simultaneously. By incorporating on-chip timers, control over pulse timing is assigned to the chip, re- ducing by up to fourfold the amount of control data which must be sent. By incorporating on-chip RAM, information as- sociated with the desired stimulus amplitude and pulse tim- ing can be stored on chip. In this manner, it is necessary to send control information to the chip only when the infor- mation changes, rather than at the stimulus repeat rate for each channel. This further reduces the data rate by a factor of five to ten times or more. The architecture described here, implemented as an eight-channel stimulator, is scalable to a 625-channel stimulator while keeping data transmission rates under 2 Mbps.Keywords
This publication has 14 references indexed in Scilit:
- A transcutaneous power and data link for neuroprosthetic applicationsPublished by Institute of Electrical and Electronics Engineers (IEEE) ,2005
- Optimizing recording capabilities of the Utah Intracortical Electrode ArrayBrain Research, 1994
- Simulation of a phosphene-based visual field: Visual acuity in a pixelized vision systemAnnals of Biomedical Engineering, 1992
- A 16-channel CMOS neural stimulating arrayIEEE Journal of Solid-State Circuits, 1992
- Multisite microprobes for neural recordingsIEEE Transactions on Biomedical Engineering, 1991
- A multiwire microelectrode for single unit recording in deep brain structuresJournal of Neuroscience Methods, 1990
- Visual sensations produced by intracortical microstimulation of the human occipital cortexMedical & Biological Engineering & Computing, 1990
- Simultaneous recording with 30 microelectrodes in monkey visual cortexExperimental Brain Research, 1981
- The sensations produced by electrical stimulation of the visual cortexThe Journal of Physiology, 1968
- Brief, Noninjurious Electric Waveform for Stimulation of the BrainScience, 1955