Comparison of impedance cardiography and dye dilution method for measuring cardiac output
Open Access
- 1 May 1998
- Vol. 79 (5) , 437-441
- https://doi.org/10.1136/hrt.79.5.437
Abstract
Objective To assess the degree of agreement between impedance cardiography, using the NCCOM3-R7 device, and the gold standard—the dye dilution method—both under basal conditions and after stimulation of cardiac output. Patients 35 paired measurements in five healthy male volunteers. Interventions To obtain higher levels of cardiac output, cardiac performance was stimulated with a dopamine infusion. Results In 35 paired measurements, the mean of all the impedance values was higher than that of the dye dilution values, at 10.2 v 7.4 l/min (p < 0.0001). The mean discrepancy between the two methods was 3.3 l/min, and the mean bias −2.9 l/min, with limits of agreement of −9.0 and 3.2 l/min. A change in cardiac output could not adequately be predicted by the NCCOM3-R7. In 20 of 25 measurements obtained during continuous intravenous dopamine infusions there was a rise in dye dilution cardiac output (range 0.2 to 5.9 l/min). Neither the magnitude nor the direction of the change in dye dilution values corresponded with the change measured by impedance cardiography. The mean discrepancy here between the two methods was 1.8 l/min, and the mean bias −0.8 l/min, with limits of agreement of −4.9 and 3.3 l/min. Conclusions In healthy volunteers, impedance cardiography with NCCOM3-R7 is inadequate for assessing cardiac output when compared with the dye dilution method.Keywords
This publication has 39 references indexed in Scilit:
- Comparison of impedance cardiography with thermodilution and direct fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathyThe American Journal of Cardiology, 1996
- Bioimpedance versus thermodilution cardiac output measurement: The bomed NCCOM3 after coronary bypass surgeryIntensive Care Medicine, 1991
- Noninvasive assessment of cardiac output in children using impedance cardiographyAmerican Heart Journal, 1990
- Validation of impedance cardiography measurements of cardiac output during limited exercise in heart transplant recipientsTransplant International, 1990
- Determination of cardiac output during positive endexpiratory pressure—Noninvasive electrical bioimpedance compared with standard thermodilutionCritical Care Medicine, 1990
- Noninvasive Cardiac Output: Simultaneous Comparison of Two Different Methods with ThermodilutionAnesthesiology, 1990
- A comparative study of cardiac output in neonates supported by mechanical ventilation: measurement with thoracic electrical bioimpedance and pulsed Doppler ultrasoundThe Journal of Pediatrics, 1989
- Use of transthoracic bioimpedance to determine cardiac output in pediatric patientsCritical Care Medicine, 1988
- Comparison of bioimpedance and thermodilution methods for determining cardiac output: Experimental and clinical studiesThe Annals of Thoracic Surgery, 1988
- Automated non-invasive measurement of cardiac output: comparison of electrical bioimpedance and carbon dioxide rebreathing techniques.Heart, 1988