Armature leakage reactance of synchronous machines has recently received considerable attention because of the important part which it plays in the accurate calculation of the performance of the saturated machine. (See, for example, reference 15 at end of this paper.) Test methods for determining the proper values of armature leakage reactance, and the results of these tests, are presented in this paper and should be of interest as an indication of the reliability of the formulas for the unsaturated value of this reactance and also as an indication of the variations in the reactance due to machine saturation. This paper is a companion paper to ``Tests on Armature Resistance of Synchronous Machines'' appearing on pages 705-9 of this issue.Keywords
This publication has 6 references indexed in Scilit:
- Calculation of Synchronous Machine Constants- Reactances and Time Constants Affecting Transient CharacteristicsTransactions of the American Institute of Electrical Engineers, 1931
- The Calculation of the Armature Reactance of Synchronous MachinesTransactions of the American Institute of Electrical Engineers, 1928
- Synchronous machines I-an extension of blondel's two-reaction theoryTransactions of the American Institute of Electrical Engineers, 1926
- Reactance of Synchronous Machines and its ApplicationsTransactions of the American Institute of Electrical Engineers, 1918
- The Transient Reactions of AlternatorsTransactions of the American Institute of Electrical Engineers, 1912
- Self-Starting Synchronous MotorsTransactions of the American Institute of Electrical Engineers, 1912