Abstract
A guarded comparator for the calibration of inductive voltage dividers against a calibrated standard is described. It features the use of a fixed RC network for phase compensations and a minimum of specialized equipment. Accuracy degradation in voltage-ratio determinations is less than ±0.05 parts per million at, typically, 1 kHz.

This publication has 0 references indexed in Scilit: