Performance of the Amplicor human immunodeficiency virus type 1 PCR and analysis of specimens with false-negative results
- 1 November 1997
- journal article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 35 (11) , 2846-53
- https://doi.org/10.1128/jcm.35.11.2846-2853.1997
Abstract
Over a 4-year period, the Roche Amplicor kit was used in a United Kingdom reference laboratory for the detection or confirmation of human immunodeficiency virus (HIV) type 1 infection, particularly in infants born to HIV-infected mothers. Of 408 specimens from adults and older children tested, the 122 seronegative specimens were all Amplicor negative. Of the 286 seropositive specimens, 268 were Amplicor positive. On the basis of these results, the Amplicor assay has a specificity of 100% and a sensitivity of 93.7%. In addition, for 247 specimens from infants and young children, serological results may not have been diagnostic because of placental transfer of maternal antibodies. Forty-eight were Amplicor positive, and of the 199 Amplicor-negative specimens, 19 were assumed to be false negative on the basis of clinical data, serological markers (including p24 antigen), and/or results for previous or follow-up specimens. This represents a sensitivity of 75% for the Amplicor test for specimens from patients under 2 years of age. Of these 37 false-negative specimens plus 2 specimens from other laboratories, 31 could be characterized by amplifying extracted material from them by an in-house nested gag PCR spanning the Amplicor target region. The amplicons were sequenced and found to represent subtypes A (35.5%), B (22.6%), C (22.6%), D (16.1%), and G (3.2%). False-negative results by the Amplicor assay may be ascribed to low-target copy number, the physical behavior of one primer (SK462), and sequence variation in the target region of the other primer (SK431).Keywords
This publication has 23 references indexed in Scilit:
- How valuable are IgA and IgM anti-HIV tests for the diagnosis of mother-child transmission of HIV in an African setting?Clinical and Diagnostic Virology, 1996
- Evaluation and comparison of the Amplicor HIV-1 PCR kit with an ‘in-house’ nested PCRClinical and Diagnostic Virology, 1995
- Comparison of a rapid nonisotopic polymerase chain reaction assay with four commonly used methods for the early diagnosis of human immunodeficiency virus type 1 infection in neonates and childrenThe Pediatric Infectious Disease Journal, 1995
- HIV Type 1 Sequence Subtype G Transmission from Mother to Infant: Failure of Variant Sequence Species to Amplify in the Roche Amplicor TestAIDS Research and Human Retroviruses, 1995
- Detection of HIV-1 proviral sequences in lymphocytes using a qualitative polymerase chain reaction assayEuropean Journal of Clinical Microbiology & Infectious Diseases, 1995
- GACPAT HIV 1+2: A simple, inexpensive assay to screen for, and discriminate between, anti‐HIV 1 and anti‐HIV 2Journal of Medical Virology, 1995
- Evaluation of the Amplicor HIV1 DNA diagnosis testResearch in Virology, 1994
- Detection of HIV‐1 sequences in children using radioactive and colorimetric polymerase chain reactionsJournal of Medical Virology, 1994
- Non-isotopic polymerase chain reaction methods for the detection of HIV-1 in Ugandan mothers and infantsAIDS, 1991
- Discordance between Primer Pairs in the Polymerase Chain Reaction for Detection of Human Immunodeficiency Virus Type 1: A Role for Taq Polymerase InhibitorsThe Journal of Infectious Diseases, 1991