Hydroxyapatite-Coated Femoral Stems. A Matched-Pair Analysis of Coated and Uncoated Implants*
- 1 March 1996
- journal article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 78 (3) , 319-24
- https://doi.org/10.2106/00004623-199603000-00001
Abstract
Fifty-two pairs of patients who had had a total hip arthroplasty with a porous-coated femoral implant were studied in a retrospective, matched-pair analysis. Half of the patients had received a femoral component coated with hydroxyapatite and the other half (the controls), an identical component but without hydroxyapatite. The patients were matched for age, sex, weight, diagnosis, Charnley class, operative approach, and duration of follow-up. Identical uncoated hemispherical acetabular implants were used in both groups. At the time of follow-up, at a mean of 2.2 years (range, two to 3.4 years) after the operation, the mean Charnley scores for pain, function, and motion were 5.6, 5.5, and 5.6 points, respectively, in the group that had received a hydroxyapatite-coated femoral component and 5.6, 5.6, and 5.6 points, respectively, in the group that had received a non-coated component; none of these differences were significant (p = 0.86, 0.89,, and 0.80, respectively). There were no revisions in either group. Radiographs indicated stable fixation in both groups and no differences in the radiographic parameters of loosening between the two groups. Within the relatively short time-frame of this study, there appeared to be no clinical or radiographic advantage to the use of hydroxyapatite in primary total hip arthroplasties. However, these results should be considered as preliminary. Longer follow-up may reveal unrecognized advantages or disadvantages.Keywords
This publication has 13 references indexed in Scilit:
- Taperloc femoral component: A 2–6-year study of the first 100 consecutive casesThe Journal of Arthroplasty, 1994
- Migration of hydroxyapatite coated femoral prostheses. A Roentgen Stereophotogrammetric studyThe Journal of Bone and Joint Surgery. British volume, 1993
- Loss of hydroxyapatite coating on retrieved, total hip componentsThe Journal of Arthroplasty, 1993
- Hydroxyapatite coating converts fibrous tissue to bone around loaded implantsThe Journal of Bone and Joint Surgery. British volume, 1993
- Hydroxyapatite coating of hip prostheses. Effect on migration into the femurThe Journal of Bone and Joint Surgery. British volume, 1992
- The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implantThe Journal of Arthroplasty, 1991
- The effect of hydroxyapatite coating on bone growth into porous titanium alloy implantsThe Journal of Bone and Joint Surgery. British volume, 1989
- Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical resultsThe Journal of Bone and Joint Surgery. British volume, 1987
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973
- THE LONG-TERM RESULTS OF LOW-FRICTION ARTHROPLASTY OF THE HIP PERFORMED AS A PRIMARY INTERVENTIONThe Journal of Bone and Joint Surgery. British volume, 1972