Accurate determination of end-tidal carbon dioxide during administration of oxygen by nasal cannulae
- 1 April 1989
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 5 (2) , 105-110
- https://doi.org/10.1007/bf01617883
Abstract
Measurement of end-tidal carbon dioxide tension (PetCO2) by mass spectrometry or infrared capnometry provides a clinically useful approximation of arterial carbon dioxide tension (PaCO2) in intubated patients. Although several devices have been proposed to samplePetCO2 during spontaneous breathing (i.e., unintubated patients receiving supplemental oxygen), thus far no reports have documented their efficacy. This article reports the use of an easily constructed modification of simple nasal cannulae that permits accurate sampling ofPetCO2 during oxygen administration to unintubated patients. After amputation of the closed tip, a cap from a syringe was inserted via a slit made at the base into one prong of a pair of nasal cannulae. A capnometer was connected to the syringe cap, andPetCO2 and PaCO2 were determined simultaneously during the administration of 3 L/min oxygen via nasal cannulae to 21 normocapnic patients. The PaCO2 —PetCO2 gradients were calculated and compared with values obtained in the same patients after intubation and mechanical ventilation. No significant difference was found between the calculated gradients with nasal cannulae (2.09±2.18 mm Hg) versus intubation (2.87±2.82 mm Hg). Simultaneous oxygen administration and accurate sampling ofPetCO2 may be achieved in unintubated patients by using this easily constructed modification of nasal cannulae.Keywords
This publication has 14 references indexed in Scilit:
- Accuracy of Expired Carbon Dioxide Partial Pressure Sampled from a Nasal Cannula. IIAnesthesiology, 1988
- Accuracy of Expired Carbon Dioxide Partial Pressure Sampled from a Nasal Cannula. IIAnesthesiology, 1988
- Accuracy of Expired Carbon Dioxide Partial Pressure Sampled from a Nasal Cannula. IAnesthesiology, 1988
- A Simple, Easy, and Inexpensive Method for Monitoring ETCO2 through Nasal CannulaeAnesthesiology, 1987
- A Simpler Design for Mass Spectrometer Monitoring of the Awake PatientAnesthesiology, 1986
- Better Designs for Mass Spectrometer Monitoring of the Awake PatientAnesthesiology, 1986
- Mass Spectrometer Monitoring of Patients with Regional AnesthesiaAnesthesiology, 1985
- Variation in PCO2 between Arterial Blood and Peak Expired Gas during AnesthesiaAnesthesia & Analgesia, 1983
- Effects of Varying Respiratory Waveforms on Gas ExchangeAnesthesiology, 1967
- EFFECT ON PULMONARY GAS EXCHANGE OF VARIATIONS IN INSPIRATORY FLOW RATE DURING INTERMITTENT POSITIVE PRESSURE VENTILATIONBritish Journal of Anaesthesia, 1966