Reproducibility of assessment of myocardial function using gated 99Tcm-MIBI SPECT and quantitative software
- 1 December 2000
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 21 (12) , 1127-1134
- https://doi.org/10.1097/00006231-200012000-00006
Abstract
Purpose We investigated the reproducibility of the quantification of left ventricular volumes and ejection fraction, and grading of myocardial wall motion and systolic thickening with gated myocardial single-photon emission computed tomography (SPECT) and Cedars quantification software. Patients, materials and methods We performed post-stress gated myocardial SPECT in 33 consecutive patients twice sequentially in situ. Sixteen frames per cycle were used for gating. Using Cedars quantitative gated SPECT software ventricular volumes and ejection fraction (EF) were calculated. Wall motion and thickening was graded using 5- and 4-point scores, respectively. Coefficients of variation for re-examination of volumes and EF were calculated. Kappa values for assessing reproducibility of wall motion or wall thickening were calculated. Results Root mean square of errors was 5.0 ml for end-diastolic volume, 3.9 ml for end-systolic volume and 1.9% for EF. No bias or difference was found between the first and second acquisition by Bland-Altman analysis. Kappa values for wall motion and thickening of repeated acquisition was 0.76 and 0.87, respectively. The value of 2 SD from Bland-Altman analysis was 14.4 ml for EDV, 11.2 ml for ESV and 5.3% for EF. Conclusion We conclude that quantification of functional indices and assessment of wall motion or thickening using gated 99Tcm-sestamibi (MIBI) SPECT was reproducible and we found that their ranges of physiological fluctuation were narrow enough.Keywords
This publication has 10 references indexed in Scilit:
- Value of Gating of Technetium-99m Sestamibi Single-Photon Emission Computed Tomographic ImagingJournal of the American College of Cardiology, 1997
- Automatic Quantitation of Regional Myocardial Wall Motion and Thickening From Gated Technetium-99m Sestamibi Myocardial Perfusion Single-Photon Emission Computed TomographyJournal of the American College of Cardiology, 1997
- Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: Comparison between two algorithms working in three-dimensional spaceJournal of Nuclear Cardiology, 1997
- Evaluation of ventricular ejection fraction, wall motion, wall thickening, and other parameters with gated myocardial perfusion single-photon emission computed tomographyJournal of Nuclear Cardiology, 1997
- Left ventricular ejection fraction from gated SPET myocardial perfusion studies: a method based on the radial distribution of count rate density across the myocardial wallEuropean Journal of Nuclear Medicine and Molecular Imaging, 1996
- Automation of gated tomographic left ventricular ejection fractionJournal of Nuclear Cardiology, 1996
- Fast technetium 99m-labeled sestamibi gated single-photon emission computed tomography for evaluation of myocardial functionJournal of Nuclear Cardiology, 1996
- Left ventricular function in patients with coronary artery disease assessed by gated tomographic myocardial perfusion imagesJournal of the American College of Cardiology, 1996
- A note on the use of the intraclass correlation coefficient in the evaluation of agreement between two methods of measurementComputers in Biology and Medicine, 1990
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986