Evidence for the need of bedside accuracy of pulse oximetry in an intensive care unit
- 1 March 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 28 (3) , 703-706
- https://doi.org/10.1097/00003246-200003000-00017
Abstract
To compare pulse oximetry saturation (Spo2 with arterial blood gas saturation (SaO2) obtained during clinical routine to determine the optimal lowest reliable value of SpO2 in ventilator-dependent patients before setting up a nurse-directed protocol of FIO2 titration. Prospective clinical study. Surgical intensive care unit in a university hospital. Thirty-three patients with a pulse oximeter probe in whom arterial blood gas was measured with a radial artery line. SPO2 was recorded by the nurses and compared with SaO2 obtained by blood gas analysis with a co-oximeter. Two sensors currently used in our surgical intensive care unit and connected to a monitor (HP OmniCare M1165/66A; Hewett Packard, Andover, MA) were tested. In group I, the Durensor DS 100A (Nellcor Puritan Bennett, Pleasanton, CA), a reusable sensor, was used. In group II, the Oxisensor D25L (Nellcor Puritan Bennett), a nonreusable sensor, was used. In group 1, 64 data pairs were obtained. In this group, SaO2 ranged from 87 to 98% and SpO2 ranged from 92 to 100%. The bias was -1.90% and the limits of agreement ranged from -5.56 to 1.76%. In group 11, 47 data pairs were obtained. In this group, SaO2 ranged from 87 to 99% and SpO2 ranged from 92 to 100%. The bias was -2.49% and the limits of agreement ranged from -6.62 to 1.64%. In the range of SaO2 tested, regardless of the sensor used, SpO2 overestimated SaO2. Large limits of agreement were found. Based on this result, the authors concluded that before defining a nurse-directed protocol of FIO2 titration with SpO2, the material used daily must be evaluated. A minimum threshold SpO2 value of 96% in both groups I and II is more reliable to ensure SaO2 > or = 90%.Keywords
This publication has 15 references indexed in Scilit:
- Uses and abuses of pulse oximetry.Archives of Disease in Childhood, 1996
- Consensus Conference on Mechanical Ventilation —January 28–30, 1993 at Northbrook, Illinois, USAIntensive Care Medicine, 1994
- Randomized Evaluation of Pulse Oximetry in 20,802 Patients; IIAnesthesiology, 1993
- Randomized Evaluation of Pulse Oximetry in 20,802 Patients; IAnesthesiology, 1993
- A Nurse-Directed Protocol Using Pulse Oximetry to Wean Mechanically Ventilated Patients from Toxic Oxygen ConcentrationsChest, 1992
- Pulse Oximetry in the Postoperative Care of Cardiac Surgical PatientsChest, 1992
- Recent Developments in Pulse OximetryAnesthesiology, 1992
- Respiratory MonitoringPublished by American Medical Association (AMA) ,1990
- Oximetry—Know Thy LimitsChest, 1987
- Measurement in Medicine: The Analysis of Method Comparison StudiesJournal of the Royal Statistical Society: Series D (The Statistician), 1983