G-CSF and Erythropoietin Stability in Amniotic Fluid during Simulated in vitro Digestion Conditions
- 1 November 2002
- journal article
- research article
- Published by SAGE Publications in Journal of Pharmacy Technology
- Vol. 18 (6) , 310-315
- https://doi.org/10.1177/875512250201800603
Abstract
Objective: To determine the stability of granulocyte colony-stimulating factor (G-CSF) and erythropoietin (Epo) in human amniotic fluid and recombinant G-CSF (Neupogen) and Epo (Epogen) in simulated amniotic fluid to digestions at pH concentrations of 3.2, 4.5, and 5.8 to assess their bioavailability to the neonate. Design: A simulated amniotic fluid containing Neupogen and Epogen was subjected to in vitro conditions that mimicked preprandial and postprandial neonatal intestinal digestion. Human amniotic fluid was tested using identical digestion conditions as well as human amniotic fluid to which Epogen and Neupogen had been added. Main Outcome Measures: The percentages of G-CSF/Epo and Neupogen/Epogen remaining after 1 and 2 hours of simulated digestions were compared with those at time zero, and concentrations at 2 hours were compared with those at 1 hour and time zero. Results: In simulated amniotic fluid at pH 3.2, significant degradation of G-CSF was observed at 1 hour (p = 0.03). No differences were observed at 1 or 2 hours for either pH 4.5 (p = 0.30 and 0.11, respectively) or pH 5.8 (p = 0.20 and 0.49, respectively). Human amniotic fluid exhibited significant degradation pH 3.2 (p = 0.04) and pH 4.5 (p < 0.05) at 1 hour; no difference was noted at pH 5.8 at 1 hour (p = 0.34). When additional Neupogen was added to human amniotic fluid, significant degradation was observed at pH 3.2 (p < 0.05) and pH 4.5 (p = 0.03) at 1 hour; no difference was noted at 1 hour at pH 5.8 (p = 0.11). In simulated amniotic fluid at pH 3.2, significant degradation of Epo occurred at 1 hour (p < 0.05). There were no differences at 1 hour for pH 4.5 (p = 0.50) or pH 5.8 (p = 0.17). Human amniotic fluid exhibited significant degradation at pH 3.2 (p < 0.05) and pH 4.5 (p < 0.05) at 1 hour; no difference was noted at 1 hour at pH 5.8 (p = 0.34). When additional Epogen was added to human amniotic fluid, significant degradation was observed at pH 3.2 (p = 0.001) and pH 4.5 (p = 0.003); no difference was noted at 1 hour at pH 5.8 (p = 0.31). Conclusions: G-CSF/Epo in human amniotic fluid and Neupogen/Epogen in simulated amniotic fluid are preserved to varying degrees during simulated digestion conditions. The degree of degradation of both cytokines was time- and pH-dependent. Measurable quantities of G-CSF and Epo are biologically available when swallowed by the fetus or a preterm neonate.Keywords
This publication has 26 references indexed in Scilit:
- Erythropoietin acts as a trophic factor in neonatal rat intestineGut, 2001
- Human Milk as a Potential Enteral Source of ErythropoietinPediatric Research, 1998
- Esophageal Ligation: Effects on the Development of Fetal Organic Systems*European Journal of Pediatric Surgery, 1996
- Parenteral Nutrition Is Associated With Intestinal Morphologic and Functional Changes in HumansJournal of Parenteral and Enteral Nutrition, 1995
- The effect of regular maternal exercise on erythropoietin in cord blood and amniotic fluidAmerican Journal of Obstetrics and Gynecology, 1995
- Restitution of Swallowing in the Fetal Sheep Restores Intestinal Growth after Midgestation Esophageal ObstructionJournal of Pediatric Gastroenterology and Nutrition, 1995
- Effect of Glutamine‐Supplemented Total Parenteral Nutrition on Recovery of the Small Intestine After Starvation AtrophyJournal of Parenteral and Enteral Nutrition, 1993
- The effects of total parenteral nutrition on gastrointestinal growth and developmentJournal of Pediatric Surgery, 1985
- COMPOSITION OF AMNIOTIC FLUID AND MATERNAL BLOOD THROUGH PREGNANCYBJOG: An International Journal of Obstetrics and Gynaecology, 1971
- THE VOLUME AND COMPOSITION OF AMNIOTIC FLUID IN EARLY PREGNANCYBJOG: An International Journal of Obstetrics and Gynaecology, 1970