Loss of image quality in photobleaching during microscopic imaging of fluorescent probes bound to chromatin
- 1 January 2005
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 10 (6) , 064015-064015-9
- https://doi.org/10.1117/1.2136313
Abstract
Prolonged excitation of fluorescent probes leads eventually to loss of their capacity to emit light. A decrease in the number of detected photons reduces subsequently the resolving power of a fluorescence microscope. Adverse effects of fluorescence intensity loss on the quality of microscopic images of biological specimens have been recognized, but not determined quantitatively. We propose three human-independent methods of quality determination. These techniques require no reference images and are based on calculation of the actual resolution distance, information entropy, and signal-to-noise ratio (SNR). We apply the three measures to study the effect of photobleaching in cell nuclei stained with propidium iodide (PI) and chromomycin A3 and imaged with fluorescence confocal microscopy. We conclude that the relative loss of image quality is smaller than the corresponding decrease in fluorescence intensity. Furthermore, the extent of quality loss is related to the optical properties of the imaging system and the noise characteristics of the detector. We discuss the importance of these findings for optimal registration and compression of biological images.
Keywords
This publication has 34 references indexed in Scilit:
- Minimizing photobleaching during confocal microscopy of fluorescent probes bound to chromatin: role of anoxia and photon fluxJournal of Microscopy, 2004
- Quantitative NAD(P)H/Flavoprotein Autofluorescence Imaging Reveals Metabolic Mechanisms of Pancreatic Islet Pyruvate ResponseJournal of Biological Chemistry, 2004
- Imaging Below the Diffraction Limit: A Statistical AnalysisIEEE Transactions on Image Processing, 2004
- Video quality assessment based on structural distortion measurementSignal Processing: Image Communication, 2003
- Bivariate shrinkage functions for wavelet-based denoising exploiting interscale dependencyIEEE Transactions on Signal Processing, 2002
- Coherent model-based optical resolutionJournal of the Optical Society of America A, 1996
- Quantitative microscopyIEEE Engineering in Medicine and Biology Magazine, 1996
- Reduction of the rate of fluorescence decay of FITC- and carboxyfluorescein-stained cells by anti-FITC antibodiesJournal of Molecular Histology, 1992
- Optical resolution: an analysis based on catastrophe theoryJournal of the Optical Society of America A, 1987
- Properties of a Defocused Optical System*Journal of the Optical Society of America, 1969