The Four-Electrode Resistivity Technique as Applied to Cardiac Muscle
- 1 July 1982
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. BME-29 (7) , 541-546
- https://doi.org/10.1109/tbme.1982.324927
Abstract
Cardiac tissue consists of two conducting regions, the intracellular and the interstitial, which are separated by a plasma membrane. It therefore constitutes a bidomain, as distinct from a single (monodomain) conducting region. Each cardiac domain is anisotropic.Keywords
This publication has 9 references indexed in Scilit:
- Intramural resistivity of cardiac tissueMedical & Biological Engineering & Computing, 1979
- Influence of cardiac fiber orientation on wavefront voltage, conduction velocity, and tissue resistivity in the dog.Circulation Research, 1979
- Simulation studies of the electrocardiogram. I. The normal heart.Circulation Research, 1978
- Directional differences of impulse spread in trabecular muscle from mammalian heart.The Journal of Physiology, 1976
- Biological Information Processing Using the Concept of Interpenetrating DomainsPublished by Springer Nature ,1969
- Four-Electrode Null Techniques for Impedance Measurement with High ResolutionReview of Scientific Instruments, 1968
- The specific resistance of biological material—A compendium of data for the biomedical engineer and physiologistMedical & Biological Engineering & Computing, 1967
- Resistivity of Body Tissues at Low FrequenciesCirculation Research, 1963
- Methods of measuring the resistivities of anisotropic conducting media in situJournal of Research of the National Bureau of Standards, Section C: Engineering and Instrumentation, 1962