Testing the Limits of ICP‐MS: Determination of Trace Elements in Ground Water at the Part‐Per‐Trillion Level
- 1 November 1994
- journal article
- Published by Wiley in Groundwater
- Vol. 32 (6) , 976-985
- https://doi.org/10.1111/j.1745-6584.1994.tb00937.x
Abstract
An ICP‐MS, equipped with an ultrasonic nebulizer and active‐film multiplier detector, is used to attempt to determine 54 trace elements directly in ground water. Lithium, arsenic, rubidium, strontium, barium, and antimony are found in the microgram‐per‐liter (part‐per‐billion = ppb) range. Most of the other elements are present at nanogram‐per‐liter (part‐per‐trillion = ppt) concentrations. Ion exchange preconcentration is utilized in order to improve the sensitivity for measuring the rare earth elements that exist at concentrations as low as 0.05 ppt for lutetium, thulium, and terbium. The formation of molecular species in the plasma produces false positive results for some of the elements. The presence of silicon or carbon dioxide interferes with the measurement of scandium, strontium interferes with rhodium and palladium, and barium interferes with europium. Correction procedures for these interferences are discussed. All together, the concentrations of the 54 elements in water from four Nevada springs span almost seven orders of magnitude.Keywords
This publication has 16 references indexed in Scilit:
- Analytical chemistry and oceanographyAnalytical Chemistry, 1992
- Water-in-oil microemulsions as solvents for laser-excited multiphoton photoionizationAnalytical Chemistry, 1992
- The use of ICP-MS for the analysis of natural waters and an evaluation of sampling techniquesEnvironmental Geochemistry and Health, 1991
- LANTHANOIDS AND ACTINOIDS IN TERRESTRIAL WATER IN JAPAN AS DETERMINED BY HIGH RESOLUTION ICP-MS WITH AN ULTRASONIC NEBULIZERAnalytical Sciences, 1991
- Determination of trace lanthanides and yttrium in seawater by inductively coupled plasma mass spectrometry after preconcentration with solvent extraction and back-extractionAnalytical Chemistry, 1990
- The influence of polyatomic ion interferences in analysis by inductively coupled plasma source mass spectrometry (ICP-MS)Spectrochimica Acta Part B: Atomic Spectroscopy, 1987
- Stable isotope dilution analysis of hydrologic samples by inductively coupled plasma mass spectrometryAnalytical Chemistry, 1987
- Determination of the rare-earth elements in geological materials by inductively coupled plasma mass spectrometryAnalytical Chemistry, 1987
- Rare-earth element geochemistry of standard sediments: A study using inductively coupled plasma spectrometryChemical Geology, 1985
- Determination of trace and ultratrace quantities of rare earth elements by ion exchange chromatography-mass spectrographyAnalytical Chemistry, 1974