Bronchial airway deposition and retention of particles in inhaled boluses: effect of anatomic dead space
Open Access
- 1 August 1998
- journal article
- clinical trial
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 85 (2) , 685-694
- https://doi.org/10.1152/jappl.1998.85.2.685
Abstract
The fractional deposition of particles in boluses delivered to shallow lung depths and their subsequent retention in the airways may depend on the relative volume and size of an individual’s airways. To evaluate the effect of variable anatomic dead space (ADS) on aerosol bolus delivery we had healthy subjects inhale radiolabeled, monodisperse aerosol (99mTc-iron oxide, 3.5 μm mean mondispersed aerosol diameter) boluses (40 ml) to a volumetric front depth of 70 ml into the lung at a lung volume of 70% total lung capacity end inhalation. By using filter techniques, aerosol photometry, and gamma camera analysis, we estimated the fraction of the inhaled boluses deposited in intrathoracic airways (IDF). ADS by single-breath N2 washout was also measured from 70% total lung capacity. Results showed that among all subjects IDF was variable (range = 0.04–0.43, coefficient of variation = 0.54) and increased with decreasing ADS ( r = −0.76, P = 0.001, n = 16). We found significantly greater deposition in the left (L) vs. right (R) lungs; mean L/R (ratio of deposition in L lung to R lung, normalized to ratio of L-to-R lung volume) was 1.58 ± 0.42 (SD; P < 0.001 for comparison with 1.0). Retention of deposited particles at 2 h was independent of ADS or IDF. There was significant retention of particles at 24 h postdeposition (0.27 ± 0.05) and slow clearance of these particles continued through 48 h postdeposition. Finally, analysis of central-to-peripheral ratios of initial deposition and 24-h-retention gamma-camera images suggest significant retention of insoluble particles in large bronchial airways at 24 h postdeposition (i.e., 24 h central-to-peripheral ratio = 1.40 ± 0.44 and 1.82 ± 0.54 in the R and L lung, respectively; P < 0.02 for comparison with 1.0). These data may prove useful for 1) designing aerosol delivery techniques to target bronchial airways and 2) understanding airway retention of inhaled particles.Keywords
This publication has 20 references indexed in Scilit:
- Human Deposition and Clearance of 6-μm Particles Inhaled with an Extremely Low Flow RateExperimental Lung Research, 1995
- Pulmonary Clearance of Inhaled Particles 24 to 48 Hours Post Deposition: Effect of Beta-Adrenergic StimulationJournal of Aerosol Medicine, 1993
- Aerosol-derived lung morphometry: comparisons with a lung model and lung function indexesJournal of Applied Physiology, 1991
- Targeting Respiratory Drug Delivery with Aerosol BolusesJournal of Aerosol Medicine, 1991
- Dual Pathway Clearance of99mTc-DTPA from the Bronchial MucosaAmerican Review of Respiratory Disease, 1989
- The Use of Light Scattering Photometry in Aerosol MedicineJournal of Aerosol Medicine, 1988
- Effect of inspiratory flow rate on regional distribution of inspired gas.Journal of Applied Physiology, 1974
- Models of the human bronchial tree.Journal of Applied Physiology, 1971
- Regional ventilation of the lung, studied with boluses of 133xenonRespiration Physiology, 1967
- LUNG FUNCTION STUDIES. II. THE RESPIRATORY DEAD SPACEAmerican Journal of Physiology-Legacy Content, 1948