Pulsed Gas Introduction for Increasing Peptide CID Efficiency in a MALDI/Quadrupole Ion Trap Mass Spectrometer
- 1 February 1996
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 68 (3) , 463-472
- https://doi.org/10.1021/ac950954l
Abstract
A pulsed valve was used for studying the effects of introducing heavy gases at different stages of operation of a quadrupole ion trap and for increasing the efficiency of collision-induced dissociation (CID) of peptide ions at low values of the Mathieu parameter qz. When amounts of heavy gases comparable to that of the helium buffer gas were introduced during the ion trapping, ion isolation, and mass spectral recording stages, the effects on performance were generally small or negative. However, injection of heavy gases during CID provided considerable improvement in fragmentation efficiency that depended upon the particular gas used, its mass and pressure, and the amplitude of the excitation voltage. Efficient peptide fragmentation could be demonstrated for values of qz as low as 0.05, which permitted trapping of low-mass product ions and (in many cases) full recovery of the amino acid sequence. In this report, examples are provided of monoisotopic tandem mass spectra of peptide ions with masses up to 1570 Da.Keywords
This publication has 21 references indexed in Scilit:
- High-Performance Collision-Induced Dissociation of Peptide Ions Formed by Matrix-Assisted Laser Desorption/Ionization in a Quadrupole Ion Trap Mass SpectrometerAnalytical Chemistry, 1995
- Linear mass calibration in the quadrupole ion-trap mass spectrometerRapid Communications in Mass Spectrometry, 1994
- A new method of trapping ions produced by matrix‐assisted laser desorption lonization in a quadrupole ion trapRapid Communications in Mass Spectrometry, 1993
- Efficient trapping and collision-induced dissociation of high-mass cluster ions using mixed target gases in the quadrupole ion trapRapid Communications in Mass Spectrometry, 1992
- Quadrupole ion trap mass spectrometry of fullerenesJournal of Mass Spectrometry, 1992
- A study of relevant parameters in collisional‐activation of ions in the ion‐trap mass spectrometerRapid Communications in Mass Spectrometry, 1990
- Coupling of an atmospheric-samling ion source with an ion-trap mass spectrometerAnalytica Chimica Acta, 1989
- Recent improvements in and analytical applications of advanced ion trap technologyInternational Journal of Mass Spectrometry and Ion Processes, 1984
- Conversion of kinetic energy to internal energy in the 2-pentanone molecular ion at threshold in low-energy collisions with helium target atomsInternational Journal of Mass Spectrometry and Ion Processes, 1984
- Metastable ion characteristics. VII. Collision-induced metastablesJournal of the American Chemical Society, 1968