Optimization of the arterial input function for myocardial perfusion cardiovascular magnetic resonance
Open Access
- 18 March 2005
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 21 (4) , 354-359
- https://doi.org/10.1002/jmri.20294
Abstract
Purpose: To determine how injection rate, cardiac function, and breathhold influence the arterial input function (AIF), in order to optimize the AIF in the clinical setting for quantitative myocardial perfusion cardiovascular magnetic resonance (CMR).Materials and Methods: Gd (0.1 mmol/kg) bolus was injected at 3, 5, or 7 mL/second in 35 patients. In each cardiac cycle during the first‐pass, a series of saturation recovery (SR) fast low‐angle shot (FLASH) low resolution images with exponentially increasing SR delay times were acquired. Signal intensity (SI) time measurements were made from a region of interest (ROI) drawn in the ascending aorta (AA). The calculation of short T1s and thus peak Gd concentration [Gd] was performed by fitting the mean ROI SI against SR delay times.Results: The mean peak [Gd] in the AA increased as injection rate increased from 3 mL/second (5.0 mM), to 5 mL/second (7.1 mM), to 7 mL/second (4 mM) (P < 0.0001). The peak [Gd] increased as the left ventricular stroke volume (LV SV) increased (P = 0.01). Breath holding was not found to influence peak [Gd].Conclusion: In this study, we found that a high injection rate has advantages over lower injection speeds, although the duration of the AIF was apparently not significantly shortened by faster injection. The choice of expiration or inspiration as breathhold did not have a significant influence upon the AIF. Poor cardiac function was associated with a lower peak [Gd], indicating that first pass perfusion measurements in these patients will be suboptimal. J. Magn. Reson. Imaging 2005;21:354–359.Keywords
This publication has 12 references indexed in Scilit:
- Accurate assessment of the arterial input function during high‐dose myocardial perfusion cardiovascular magnetic resonanceJournal of Magnetic Resonance Imaging, 2004
- Influence of Arterial Input Function on Hypoperfusion Volumes Measured With Perfusion-Weighted ImagingStroke, 2004
- Noninfarcted Myocardium: Correlation between Dynamic First-Pass Contrast-enhanced Myocardial MR Imaging and Quantitative Coronary AngiographyRadiology, 2003
- Magnetic Resonance Perfusion Measurements for the Noninvasive Detection of Coronary Artery DiseaseCirculation, 2003
- Assessment of Myocardial Perfusion in Coronary Artery Disease by Magnetic ResonanceCirculation, 2001
- Differences in injection rates on contrast-enhanced breath-hold three-dimensional MR angiography.American Journal of Roentgenology, 1998
- Magnetic resonance quantification of the myocardial perfusion reserve with a Fermi function model for constrained deconvolutionMedical Physics, 1998
- Multislice MRI in Assessment of Myocardial Perfusion in Patients With Single-Vessel Proximal Left Anterior Descending Coronary Artery Disease Before and After RevascularizationCirculation, 1997
- Myocardial perfusion modeling using MRIMagnetic Resonance in Medicine, 1996
- Influence of bolus volume and dose of gadolinium chelate for first‐pass myocardial perfusion MR imaging studiesJournal of Magnetic Resonance Imaging, 1995