Quality assessment of confocal microscopy slide based systems: Performance
Open Access
- 28 June 2006
- journal article
- research article
- Published by Wiley in Cytometry Part A
- Vol. 69A (7) , 659-676
- https://doi.org/10.1002/cyto.a.20314
Abstract
Background: All fluorescence slide‐based cytometry detections systems basically include the following components: (1) an excitation light source, (2) intermediate optics, and (3) a detection device consisting of a CCD camera or a PMT. The optical principles employed is slide‐based systems are similar to those of confocal microscopes (CLSM). Methods: The following tests evaluated confocal equipment performance: dichroic reflectivity, field illumination, lens performance, laser power output, spectral registration, axial resolution, PMT reliability, and system noise. Results: Quality assurance tests provide a basis to determine if the equipment is operating correctly. Laser power, PMTs function, dichroic reflection, spectral registration, axial registration, system noise and sensitivity, lens performance and laser stability were tested colocalization of UV and visible peaks of a bead should be less than 210 nm. Interference contrast optics decrease fluorescence resolution. Conclusions: QA tests that assess CLSM system performance are also applicable to other slide‐based systems. By utilization this type of testing approach, the subjective nature of assessing the CLSM may be eliminated. These tests serve as guidelines for other investigators to ensure that their machines are providing data that is accurate with the necessary resolution, sensitivity and precision. © 2006 International Society for Analytical CytologyKeywords
This publication has 19 references indexed in Scilit:
- Wavelength and alignment tests for confocal spectral imaging systemsMicroscopy Research and Technique, 2005
- Polychromatic (eight‐color) slide‐based cytometry for the phenotyping of leukocyte, NK, and NKT subsetsCytometry Part A, 2005
- Cytomics goes 3D: Toward tissomicsCytometry Part A, 2005
- Calibration and validation of confocal spectral imaging systemsCytometry Part A, 2004
- Clinical applications of laser scanning cytometryCytometry, 2002
- Measuring tubulin content in Toxoplasma gondii : A comparison of laser-scanning confocal and wide-field fluorescence microscopyProceedings of the National Academy of Sciences, 2002
- Practical Confocal Microscopy and the Evaluation of System PerformanceMethods, 1999
- Aberration control in quantitative imaging of botanical specimens by multidimensional fluorescence microscopyJournal of Microscopy, 1996
- The Specimen Illumination Path and Its Effect on Image QualityPublished by Springer Nature ,1995
- Fundamental Limits in Confocal MicroscopyPublished by Springer Nature ,1995