Abstract
PURPOSE: To report applications of optical coherence tomography (OCT) in the management of laser in situ keratomileusis (LASIK) related problems. SETTING: Doheny Eye Institute and Department of Ophthalmology, Keck School of Medicine of the University of Southern California, Los Angeles, California, USA. METHODS: Five patients referred for LASIK-related problems were enrolled in a prospective observational study. Clinical examination, ultrasound (US) pachymetry, Placido ring slit-scanning corneal topography (Orbscan II, Bausch & Lomb), and high-speed corneal OCT were performed. RESULTS: In cases of regression and keratectasia, OCT provided thickness measurements of the cornea, flap, and posterior stromal bed. Locations of tissue loss and flap interface planes were identified in a case with a recut enhancement complication. The information was used to determine whether further laser ablation was safe, confirm keratectasia, and manage complications. Optical coherence tomography measurements of central corneal thickness agreed well with US pachymetry measurements (difference 6.4 μm ± 11.7 [SD]) (P = .026), while Orbscan significantly underestimated corneal thickness (−67.5 ± 72.5 μm) (P = .17). CONCLUSIONS: High-speed OCT provided noncontact imaging and measurement of LASIK anatomy. It was useful in monitoring LASIK results and evaluating complications.Keywords
This publication has 31 references indexed in Scilit:
- Measuring total corneal power before and after laser in situ keratomileusis with high-speed optical coherence tomographyJournal of Cataract & Refractive Surgery, 2006
- Corneal Pachymetry Mapping with High-speed Optical Coherence TomographyOphthalmology, 2006
- Flap and stromal bed thickness in laser in situ keratomileusis enhancementJournal of Cataract & Refractive Surgery, 2004
- A reliable corneal tomography system is still neededOphthalmology, 2003
- Reliability of pachymetric measurements using orbscan after excimer refractive surgeryOphthalmology, 2003
- Laser in situ keratomileusis for myopia and astigmatism: safety and efficacyOphthalmology, 2002
- Advances in Refractive SurgeryCornea, 2000
- Optical coherence tomography evaluation of the corneal cap and stromal bed features after laser in situ keratomileusis for high myopia and astigmatismOphthalmology, 2000
- Complications of laser in situ keratomileusis for the correction of myopiaOphthalmology, 1999
- Laser in situ keratomileusisLasers in Surgery and Medicine, 1990