Reducing Risk of Airborne Transmitted Infection in Hospitals by Use of Hospital Curtains
- 1 June 2008
- journal article
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 17 (3) , 252-259
- https://doi.org/10.1177/1420326x08091957
Abstract
An in-patient suffering from an airborne infectious disease should be properly isolated in a negative-pressure isolation room to prevent hospital-acquired infection. However, before the infectious status is identified by clinical diagnosis, the patient may be assigned to stay with others in a hospital ward with multiple beds. Under these circumstances, there may be a risk of infection of the neighboring patients. Therefore, reasonable infection control measures should be implemented in multi-bed hospital wards, intensive care units, among others. The use of hospital curtains as physical barriers against transmission of disease is potentially a simple but effective method to reduce the risk of infection. In this investigation, the effectiveness of hospital curtains in prevention against airborne transmission of diseases in hospital rooms was evaluated by numerical modeling analysis. A computational fluid dynamics (CFD)-statistical hybrid modeling method, which was validated by tracer gas measurements, was employed to determine the transient dispersion of airborne contaminants. It was found that among all the case studies, the use of curtains between two beds could reduce the peak concentration for each individual neighboring patient in a bioaerosol dispersion process. A curtain fully extended to the length of a bed yielded significantly higher protection than a partially extended curtain and the reduction in peak concentration could be as much as 65%.Keywords
This publication has 15 references indexed in Scilit:
- Nosocomial aspergillosis in outbreak settingsJournal of Hospital Infection, 2006
- Use of CFD Analysis in Modifying a TB Ward in Lima, PeruIndoor and Built Environment, 2006
- Microbiological Control of Airborne Contamination in HospitalsIndoor and Built Environment, 2006
- Bioaerosol Production on a Respiratory WardIndoor and Built Environment, 2006
- Use of Ozone to Reduce Bacteria and Moulds in the Air and on SurfacesIndoor and Built Environment, 2006
- Management of patients infected with airborne-spread diseases: An algorithm for infection control professionalsAmerican Journal of Infection Control, 2005
- Protecting health care workers from SARS and other respiratory pathogens: A review of the infection control literatureAmerican Journal of Infection Control, 2005
- An evaluation of portable high-efficiency particulate air filtration for expedient patient isolation in epidemic and emergency responseAnnals of Emergency Medicine, 2004
- Bed occupancy and overcrowding as determinant factors in the incidence of MRSA infections within general ward settingsJournal of Hospital Infection, 2003
- The effect of increased bed numbers on MRSA transmission in acute medical wardsJournal of Hospital Infection, 1998