Denoising of electron beam Monte Carlo dose distributions using digital filtering techniques
- 26 June 2000
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 45 (7) , 1765-1779
- https://doi.org/10.1088/0031-9155/45/7/305
Abstract
The Monte Carlo (MC) method has long been viewed as the ultimate dose distribution computational technique. The inherent stochastic dose fluctuations (i.e. noise), however, have several important disadvantages: noise will affect estimates of all the relevant dosimetric and radiobiological indices, and noise will degrade the resulting dose contour visualizations. We suggest the use of a post-processing denoising step to reduce statistical fluctuations and also improve dose contour visualization. We report the results of applying four different two-dimensional digital smoothing filters to two-dimensional dose images. The Integrated Tiger Series MC code was used to generate 10 MeV electron beam dose distributions at various depths in two different phantoms. The observed qualitative effects of filtering include: (a) the suppression of voxel-to voxel (high-frequency) noise and (b) the resulting contour plots are visually more comprehensible. Drawbacks include, in some cases, slight blurring of penumbra near the surface and slight blurring of other very sharp real dosimetric features. Of the four digital filters considered here, one, a filter based on a local least-squares principle, appears to suppress noise with negligible degradation of real dosimetric features. We conclude that denoising of electron beam MC dose distributions is feasible and will yield improved dosimetric reliability and improved visualization of dose distributions.Keywords
This publication has 7 references indexed in Scilit:
- Towards the elimination of Monte Carlo statistical fluctuation from dose volume histograms for radiotherapy treatment planningPhysics in Medicine & Biology, 1999
- Clinical implementation of a Monte Carlo treatment planning systemMedical Physics, 1999
- Monte Carlo-based inverse treatment planningPhysics in Medicine & Biology, 1999
- 3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC)Medical Physics, 1996
- A comparison of one-dimensional and two-dimensional smoothing algorithms for Auger depth profilingJournal of Vacuum Science & Technology A, 1991
- Smoothing and Differentiation of Data by Simplified Least Squares Procedures.Analytical Chemistry, 1964
- THE TRANSFORMATION OF POISSON, BINOMIAL AND NEGATIVE-BINOMIAL DATABiometrika, 1948