Comparison Study of Different BOD Tests in the Determination of BOD7Evaluated in a Model Domestic Sewage
Open Access
- 2 July 2007
- journal article
- research article
- Published by Hindawi Limited in Journal of Analytical Methods in Chemistry
- Vol. 2007, 1-4
- https://doi.org/10.1155/2007/39761
Abstract
The aim of this research was to study the suitability of a manometric respirometric test (OECD 301F) for the determination of biological oxygen demand (BOD) in domestic wastewater. This was done by comparing four different BOD tests (a manometric respirometric test, oxygen sensor determination, iodometric titration, and UV absorption measurement) and by evaluating the BOD7 value after a short-term measurement applying the manometric respirometric test. Measurements were done in three dif-ferent laboratories. The respirometric test was performed well on municipal sewage, and the precision of results was good. There were minor deviations between BOD7 values as determined by the different methods, but the deviations were not essentially big enough to have a practical impact. Evaluation of the BOD7 value after two or three days' incubation by the respirometric method was shown to work well; average deviations between measured and evaluated values after three days' incubation were 5–18%. Hence, the manometric respirometric test proved to be a rapid and suitable tool for process control purposes.Keywords
This publication has 7 references indexed in Scilit:
- Comparison Study of Manometric Respirometric Test and Common Chemical Methods in the Determination of BOD7 in a Pulp and Paper Mill′s WastewatersJournal of Analytical Methods in Chemistry, 2006
- Studies of biodegradability of certain oils in forest soil as determined by the respirometric BOD OxiTop methodInternational Journal of Environmental Analytical Chemistry, 2005
- Biodegradability Studies of Certain Wood Preservatives in Groundwater as Determined by the Respirometric Bod Oxitop MethodWater, Air, & Soil Pollution, 2005
- Biodegradabilities of some chain oils in groundwater as determined by the respirometric BOD OxiTop methodAnalytical and Bioanalytical Chemistry, 2004
- Suitability of the Respirometric Bod Oxitop Method for Determining the Biodegradability of Oils in Ground Water using Forestry Hydraulic Oils as Model CompoundsInternational Journal of Environmental Analytical Chemistry, 2004
- Microbial BOD sensors for wastewater analysisWater Research, 2002
- Immobilised activated sludge based biosensor for biochemical oxygen demand measurementBiosensors and Bioelectronics, 2000