Two Transformer Method for Electrodeless Conductivity Measurement

Abstract
An analysis of the two transformer system is presented. It is found that there is a frequency region in which the voltage transfer is proportional to the sample conductance. A comparison is made between the measured and predicted behavior of a two transformer system. The good agreement obtained indicates that the method of analysis can be used as an aid to designing two transformer conductivity measuring systems.