Simple and accurate way for estimating total and segmental arterial compliance: The pulse pressure method
- 1 July 1994
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 22 (4) , 392-397
- https://doi.org/10.1007/bf02368245
Abstract
We derived and tested a new, simple, and accurate method to estimate the compliance of the entire arterial tree and parts thereof. The method requires the measurements of pressure and flow and is based on fitting the pulse pressure (systolic minus diastolic pressure) predicted by the two-element windkessel model to the measured pulse pressure. We show that the two-element windkessel model accurately describes the modulus of the input impedance at low harmonics (0–4th) of the heart rate so that the gross features of the arterial pressure wave, including pulse pressure, are accounted for. The method was tested using a distributed nonlinear model of the human systemic arterial tree. Pressure and flow were calculated in the ascending aorta, thoracic aorta, common carotid, and iliac artery. In a linear version of the systemic model the estimated compliance was within 1% of the compliance at the first three locations. In the iliac artery an error of 7% was found. In a nonlinear version, we compared the estimates of compliance with the average compliance over the cardiac cycle and the compliance at the mean working pressure. At the first three locations we found the estimated and “actual” compliance to be within 12% of each other. In the iliac artery the error was larger. We also investigated an increase and decrease in heart rate, a decrease in wall elasticity and exercise conditions. In all cases the estimated total arterial compliance was within 10% of mean compliance. Thus, the errors result mainly from the nonlinearity of the arterial system. Segmental compliance can be obtained by subtraction of compliance determined at two locations.Keywords
This publication has 18 references indexed in Scilit:
- Computer simulation of arterial flow with applications to arterial and aortic stenosesJournal of Biomechanics, 1992
- Non-invasive estimate of the mechanical properties of peripheral arteries from ultrasonic and photoplethysmographic measurementsClinical Physics and Physiological Measurement, 1991
- Arterial Compliance — Physiological ViewpointPublished by Springer Nature ,1989
- Effect of nitroglycerin on aortic impedance, diameter, and pulse-wave velocity.Circulation Research, 1988
- The Effects of Finite Wave Velocity and Discrete Reflections on Ventricular LoadingPublished by Springer Nature ,1987
- Systemic compliance: does it play a role in the genesis of essential hypertension?Cardiovascular Research, 1984
- The static elastic properties of 45 human thoracic and 20 abdominal aortas in vitro and the parameters of a new modelJournal of Biomechanics, 1984
- ARTERIAL COMPLIANCE IN HYPERTENSIONAustralian and New Zealand Journal of Medicine, 1976
- Pressure and Flow Generated by the Left Ventricle against Different ImpedancesCirculation Research, 1973
- Input Impedance of the Systemic CirculationCirculation Research, 1967