A Novel Microporous Polyurethane Vascular Graft: In Vivo Evaluation of the UTA Prosthesis Implanted as Infra-Renal Aortic Substitute in Dogs
- 1 January 1993
- journal article
- research article
- Published by Taylor & Francis in Journal of Investigative Surgery
- Vol. 6 (3) , 273-288
- https://doi.org/10.3109/08941939309141617
Abstract
A novel microporous polyurethane blood conduit developed at the University of Texas at Arlington was implanted as an infra-renal substitute in dogs. The prosthesis was fabricated by precipitating a solution of the polymer with dry nitrogen onto a rotating mandrel. The grafts were sterilized either by gamma radiation (series I) or ethylene oxide (series II); they were implanted for the following prescheduled periods: 4, 24, 48 hours, and J week (short-term) and 2, 4 weeks, 3 and 6 months (medium-term). The thrombohematological characteristics of each animal were evaluated prior to implantation and confirmed that the index of blood coagulability was normal. In the short-term group, five out of eight grafts were patent and three were partially occluded; four grafts in the medium-term group were patent; one was partially occluded; and three were thrombosed at retrieval. One week after implantation, the prostheses were surrounded by an external capsule, which was present mainly at the two anastomoses. The external capsule covered the entire graft at 3 months. No kinking of the grafts was observed and the presence of a mild yellow stain related to bilirubin uptake was detected at 2 weeks, 1, 3, and 6 months. Histological studies have revealed the formation of a thin internal capsule at both anastomoses, 2 weeks postimplantation, which was not anchored to the graft wall. In the medium-term group, the thrombosed grafts failed to develop an internal capsule, whereas the patent graft exhibited a thick internal capsule made of neocollagenous tissue over the entire graft. This new microporous polyurethane prosthesis did not perform satisfactorily as an infra-renal substitute in dogs and its in vivo stability requires further assessment. Thus, the concept of a polyurethane with closed pores does not achieve what was anticipated.Keywords
This publication has 17 references indexed in Scilit:
- In vivo evaluation of four chemically processed biological grafts implanted as infrarenal arterial substitutes in dogsBiomaterials, 1989
- An X-ray photoelectron spectroscopy study of the external surface of explanted microporous polyurethane vascular prosthesesBiomaterials, 1987
- Microporous hydrophilic polyurethane vascular grafts as substitutes in the abdominal aorta of dogsBiomaterials, 1986
- Pathologic features of surgically excised human umbilical vein graftsJournal of Vascular Surgery, 1986
- Three years experience with experimental implantation of fibrous polyurethane microvascular prostheses in the rat aortaMicrosurgery, 1985
- Biodegradation and Aneurysm Formation in Umbilical Vein GraftsAnnals of Surgery, 1984
- A novel process for the manufacturing of porous grafts: Process description and product evaluationJournal of Biomedical Materials Research, 1983
- Surface modification and evaluation of some commonly used catheter materials. I. Surface propertiesJournal of Biomedical Materials Research, 1983
- Management of Polytetrafluoroethylene Graft OcclusionsArchives of Surgery, 1980
- The development of vascular surgeryThe American Journal of Surgery, 1979