Intraoperative Near‐Infrared Fluorescent Cholangiography (NIRFC) in Mouse Models of Bile Duct Injury
- 22 December 2009
- journal article
- research article
- Published by Wiley in World Journal of Surgery
- Vol. 34 (2) , 336-343
- https://doi.org/10.1007/s00268-009-0332-8
Abstract
Background Accidental injury to the common bile duct is a rare but serious complication of laparoscopic cholecystectomy. Accurate visualization of the biliary ducts may prevent injury or allow its early detection. Conventional X-ray cholangiography is often used and can mitigate the severity of injury when correctly interpreted. However, it may be useful to have an imaging method that could provide real-time extrahepatic bile duct visualization without changing the field of view from the laparoscope. The purpose of the present study was to test a new near-infrared (NIR) fluorescent agent that is rapidly excreted via the biliary route in preclinical models to evaluate intraoperative real-time near infrared fluorescent cholangiography (NIRFC). Methods To investigate probe function and excretion, a lipophilic near-infrared fluorescent agent with hepatobiliary excretion was injected intravenously into one group of C57/BL6 control mice and four groups of C57/BL6 mice under the following experimentally induced conditions: (1) chronic biliary obstruction, (2) acute biliary obstruction (3) bile duct perforation, and (4) choledocholithiasis, respectively. The biliary system was imaged intravitally for 1 h with near-infrared fluorescence (NIRF) with an intraoperative small animal imaging system (excitation 649 nm, emission 675 nm). Results The extrahepatic ducts and extraluminal bile were clearly visible due to the robust fluorescence of the excreted fluorochrome. Twenty-five minutes after intravenous injection, the target-to-background ratio peaked at 6.40 ± 0.83 but signal was clearly visible for ~60 min. The agent facilitated rapid identification of biliary obstruction and bile duct perforation. Implanted beads simulating choledocholithiasis were promptly identifiable within the common bile duct lumen. Conclusions Near-infrared fluorescent agents with hepatobiliary excretion may be used intraoperatively to visualize extrahepatic biliary anatomy and physiology. Used in conjunction with laparoscopic imaging technologies, the use of this technique should enhance hepatobiliary surgery.Keywords
This publication has 38 references indexed in Scilit:
- Three-dimensional fluorescence-enhanced optical tomography using a hand-held probe based imaging systemMedical Physics, 2008
- Real-time intraoperative assessment of the extrahepatic bile ducts in rats and pigs using invisible near-infrared fluorescent lightSurgery, 2008
- Fluorescent cholangiography in a mouse model: an innovative method for improved laparoscopic identification of the biliary anatomySurgical Endoscopy, 2006
- Intraoperative cholangiography and bile duct injurySurgical Endoscopy, 2005
- Ten-year trend in the national volume of bile duct injuries requiring operative repairSurgical Endoscopy, 2005
- Surgical Management of Bile Duct Injuries Sustained During Laparoscopic CholecystectomyAnnals of Surgery, 2005
- Surgeons’ anonymous response after bile duct injury during cholecystectomyThe American Journal of Surgery, 2003
- CASE REPORT: Radiological and endoscopic management of bile leak following laparoscopic cholecystectomyJournal of Gastroenterology and Hepatology, 1997
- Indocyanine Green Staining for Visualization of the Biliary System during Laparoscopic CholecystectomyEndoscopy, 1992
- Non-invasive in vivo near-infrared optical measurement of the penetration depth in the neonatal headClinical Physics and Physiological Measurement, 1991