Intraocular silicone lenses in silicone oil: an experimental study
- 1 January 1996
- journal article
- research article
- Published by Springer Nature in Albrecht von Graefes Archiv für Ophthalmologie
- Vol. 234 (1) , 55-57
- https://doi.org/10.1007/bf00186519
Abstract
• Background: To evaluate a potential effect of silicone oil on flexible silicone intraocular lenses, four lenses (STAAR AA-4203) were stored in silicone oil under sterile conditions for periods between 1 month and 3 years. • Method: The edge and surface of the lenses were examined by scanning electron micrography and the findings compared with a lens of the same model which had been stored in Ringer's solution for 2 years. • Results: After 1 year of silicone oil exposure, droplets of different sizes adherent to the surface of the lens were found. These changes proceeded to a wave-like appearance of the surface after 2 and 3 years of storage, so that a continuous layer of silicone oil polymers is probably covering the intraocular lens. • Conclusion: Optical interference has to be considered a possibility if it turns out that the droplets cannot be removed during silicone oil evacuation. Consequently silicone intraocular lenses without hydrophilic preparation of the surface should not be implanted in eyes undergoing combined anterior and posterior segment surgery with silicone oil tamponade or in eyes with high risk for vitreoretinal complications.Keywords
This publication has 16 references indexed in Scilit:
- No-stitch, small incision cataract surgery with flexible intraocular lens implantationJournal of Cataract & Refractive Surgery, 1994
- Combined Extracapsular Cataract Extraction, Posterior Chamber Intraocular Lens Implantation, and Pars Plana VitrectomyOphthalmic Surgery, Lasers and Imaging Retina, 1993
- Combined Phacoemulsification, Pars Plana Vitrectomy, and Posterior Chamber Intraocular Lens InsertionArchives of Ophthalmology (1950), 1992
- Scanning electron microscopic study of modern silicone intraocular lensesJournal of Cataract & Refractive Surgery, 1992
- Relative strength of cataract incisions in cadaver eyesJournal of Cataract & Refractive Surgery, 1991
- Extracapsular Cataract Extraction, Posterior Chamber Lens Insertion, and Pars Plana Vitrectomy in One OperationOphthalmology, 1990
- Posterior Chamber Intraocular Lens Insertion During Pars Plana Lensectomy and Vitrectomy for Complications of Proliferative Diabetic RetinopathyAmerican Journal of Ophthalmology, 1989
- Comparison of Complement Activation by Silicone Intraocular Lenses and Polymethylmethacrylate Intraocular Lenses With Polypropylene LoopsArchives of Ophthalmology (1950), 1987
- Are There Any Retinal Contraindications to Cataract Extraction and Posterior Chamber Lens Implants?Archives of Ophthalmology (1950), 1986
- Lipids in Silicone Rubber Valve Prostheses After Human ImplantationCirculation, 1971