Design of adiabatic selective pulses using optimal control theory
- 1 September 1996
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 36 (3) , 401-409
- https://doi.org/10.1002/mrm.1910360311
Abstract
Optimal control theory has been applied in the past for the design of RF pulses for selective excitation. This was the outcome of having established the controllability of the MR spin system for the selective excitation problem. “Minimum distance” was the main formulation used for the solution. Because of their robust behavior in the presence of inhomogeneous RF fields, adiabatic pulses play an important role in spin inversion and excitation. In this study, we present a method for incorporating adiabaticity into the optimal control problem by enhancing the cost functional with an appropriate term. Two different types of adiabatic terms are proposed. Furthermore, two methods are used to solve the optimal control problem, namely the Hamiltonian approach and the solution by mathematical programming. Design examples include both a frequency selective pulse for performing fat suppression by inversion and a regular inversion pulse. It is shown that, in the course of optimization, the pulse designer can trade-off slice resolution against pulse adiabaticity.Keywords
This publication has 13 references indexed in Scilit:
- A chemical shift selective inversion recovery sequence for fat-suppressed MRI: Theory and experimental validationMagnetic Resonance Imaging, 1993
- General solutions for tailored modulation profiles in adiabatic excitationJournal of Magnetic Resonance (1969), 1992
- Parameter relations for the Shinnar-Le Roux selective excitation pulse design algorithm (NMR imaging)IEEE Transactions on Medical Imaging, 1991
- Sweep-diagram analysis of selective adiabatic pulsesJournal of Magnetic Resonance (1969), 1989
- Optimization of modulation functions to improve insensitivity of adiabatic pulses to variations in B1 magnitudeJournal of Magnetic Resonance (1969), 1988
- Amplitude- and frequency/phase-modulated refocusing pulses that induce plane rotations even in the presence of inhomogeneous B1 fieldsJournal of Magnetic Resonance (1969), 1988
- Computer-optimized narrowband pulses for multislice imagingJournal of Magnetic Resonance (1969), 1987
- Uniform sample excitation with surface coils for in vivo spectroscopy by adiabatic rapid half passageJournal of Magnetic Resonance (1969), 1986
- Efficient adiabatic fast passage for NMR population inversion in the presence of radiofrequency field inhomogeneity and frequency offsetsJournal of Magnetic Resonance (1969), 1986
- Highly selective π2 and π pulse generationJournal of Magnetic Resonance (1969), 1984