Mathematical Analysis of Arterial Enhancement and Optimization of Bolus Geometry for CT Angiography Using the Discrete Fourier Transform
- 1 May 1999
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 23 (3) , 474-484
- https://doi.org/10.1097/00004728-199905000-00026
Abstract
The goal of this work was to develop a clinically applicable mathematical algorithm to analyze and optimize individual arterial enhancement in CT angiography (CTA). Assuming a time-invariant linear system, the discrete Fourier transform was used to calculate the transfer function of the system ("patient function") from the arterial time-attenuation response to a test bolus. The patient function was subsequently used to predict aortic enhancement in five select patients and to calculate optimized biphasic injection protocols in two of these patients undergoing CTA of the abdominal aorta. Arterial time-attenuation curves were accurately predicted in all patients. Optimized biphasic contrast agent injection protocols resulted in uniform aortic enhancement at the predefined level over the entire scanning period in both subjects despite markedly different contrast agent volumes and injection rates used. Fourier analysis of the time-attenuation response to a test bolus is a simple and feasible approach to optimize arterial enhancement in CTA.Keywords
This publication has 19 references indexed in Scilit:
- Aortic and hepatic contrast medium enhancement at CT. Part II. Effect of reduced cardiac output in a porcine model.Radiology, 1998
- Aortic and hepatic contrast medium enhancement at CT. Part I. Prediction with a computer model.Radiology, 1998
- Aortic and hepatic peak enhancement at CT: effect of contrast medium injection rate--pharmacokinetic analysis and experimental porcine model.Radiology, 1998
- Evaluation of contrast densities in the diagnosis of carotid stenosis by CT angiography.American Journal of Roentgenology, 1997
- Bolus dynamics: theoretical and experimental aspects.The British Journal of Radiology, 1997
- Comparison of tailored and empiric scan delays for CT angiography of the abdomen.American Journal of Roentgenology, 1996
- Contrast agent pharmacokinetics revisited: I. ReformulationAcademic Radiology, 1996
- Application of Pharmacokinetics to Computed TomographyInvestigative Radiology, 1996
- Determination of Scan Delay Time in Spiral CT-AngiographyJournal of Computer Assisted Tomography, 1995
- Transcoronary intravascular transport functions obtained via a stable deconvolution techniqueAnnals of Biomedical Engineering, 1976